9.5.4 Formatting drives
CPU, USR, CRD (memory card required), and USB (module required) drives can be formatted
individually. Formatting a drive erases all files on that drive. If the currently running user program
is on the drive to be formatted, the program will cease running and data associated with the
program are erased. Drive formatting is performed through the datalogger support software File
Control > Format command.
9.5.5 Full memory reset
Full memory reset occurs when an operating system is sent to the datalogger using Device
Configuration Utility or when entering
98765
in the Status table field FullMemReset (see
(p. 131)). A full memory reset does the following:
l
Clears and formats CPU drive (all program files erased)
l
Clears data tables.
l
Clears Status table fields.
l
Restores settings to default.
l
Initializes system variables.
l
Clears communications memory.
Full memory reset does not affect the CRD drive directly. Subsequent user program uploads,
however, can erase CRD. See
(p. 109) for more information.
9.6 Troubleshooting power supplies
Power supply systems may include batteries, charging regulators, and a primary power source
such as solar panels or ac/ac or ac/dc transformers attached to mains power. All components may
need to be checked if the power supply is not functioning properly. Check connections and
check polarity of connections.
Base diagnostic: connect the datalogger to a new 12 V battery. (A small 12 V battery carrying a
full charge would be a good thing to carry in your maintenance tool kit.) Ensure correct polarity
of the connection. If the datalogger powers up and works, troubleshoot the datalogger power
supply.
When diagnosing or adjusting power equipment supplied by Campbell Scientific, it is
recommended you consider:
l
Battery-voltage test
l
Charging-circuit test (when using an unregulated solar panel)
l
Charging-circuit test (when using a transformer)
l
Adjusting charging circuit