Sensor Type
Connection Example
4-wire transmitter using datalogger power
4-wire transmitter using external power
6.3
Resistance
measurements
Bridge
resistance
is
determined
by
measuring
the
difference
between
a
known
voltage
applied
to
the
excitation
(input)
of
a
resistor
bridge
and
the
voltage
measured
on
the
output
arm.
The
datalogger
supplies
a
precise
voltage
excitation
via
VX
terminals.
Return
voltage
is
measured
on
analog
ue
input
terminals
configured
for
single-ended
(SE)
or
differential
(DIFF)
input.
The
result
of
the
measurement
is
a
ratio
of
measured
voltages.
See
also
6.3.1
Resistance
measurements
with
voltage
excitation
CRBasic
instructions
for
measuring
resistance
with
voltage
excitation
include:
l
BrHalf()
- half bridge
l
BrHalf3W()
- three-wire half bridge
l
BrHalf4W()
- four-wire half bridge
l
BrFull()
- four-wire full bridge
l
BrFull6W()
- six-wire full bridge
6. Measurements