CR200 Overview
OV4. Quick Start Tutorial for Programming the
CR200
OV4.1 Software Products for the CR200
PC200W Starter Software supports a direct connection (RS232 cable or Spread
Spectrum radio) between the PC and the CR200, and includes Short Cut for
Windows (Short Cut) for creating CR200 programs. PC200W provides basic
tools for setting the datalogger’s clock, sending a program, monitoring sensors,
and manually collecting and viewing data. CR200 support was added to
PC200W in Version 3.0. PC200W is available at no charge from the Campbell
Scientific website.
PC400 Datalogger Support Software (mid-level software) supports a variety of
telecommunication options, manual data collection, and data display. PC400
includes Short Cut and the CRBasic Program Editor for creating CR200
programs. PC400 does not support combined communication options (e.g.,
phone-to-RF), PakBus® routing, or scheduled data collection.
LoggerNet Datalogger Support Software (full-featured software) supports
combined telecommunication options, data display, and scheduled data
collection. The software includes Short Cut and CRBasic for creating CR200
programs, and tools for configuring, trouble-shooting, and managing
datalogger networks.
OV4.1.1 Options for Creating CR200 Programs
1.
Short Cut is a program generator that creates a datalogger program in four
easy steps, and a wiring diagram for the sensors. Short Cut supports the
majority of sensors sold by Campbell Scientific, and is recommended for
creating straightforward programs that measure the sensors and store data.
2.
The CRBasic Editor is a program editor used to create more complex
CR200 programs. Short Cut generated programs can be imported into the
CRBasic Editor for adding instructions, or for functionality not supported
by Short Cut.
OV4.2 Connections to the CR200
Connect the CR200 to the 12V power supply and to the computer as described
in Section OV3.1.
OV4.3 PC200W Software
This Quick-Start tutorial prompts the user through the process of programming
the CR200, monitoring sensor measurements, collecting data, and viewing data
using the PC200W software. Before using PC200W, set the CR200 Pakbus
address to 1 as described in Section OV3.
When PC200W is first started, the EZSetup Wizard is launched. Click the
Next
button and follow the prompts to select the
CR200
, the
COM
port on the
computer that will be used for communications,
9600
baud, and
Pakbus
OV-16
Summary of Contents for CR200