CR200 Overview
Step 3: Output Processing
Step 3 is to define the output processing for the sensor measurements. From
the Home page, click the
Output
button.
The Output screen has a list of Selected Sensors on the left, and Output Tables
on the right. The default is for two Tables, Table1 and Table2. Both Tables
have a
Store Every
field and the drop-down list box that are used to set the
interval at which data will be stored.
The objective for this exercise calls for a one-minute output processing. To
remove Table2, Click on the
Table2
tab to activate it, and click the
Delete
Table
button.
The
Table Name
field is the name that will be used for the Table in which the
output will be stored. Change the default Name of Table1 to OneMin, and
change the interval to 1 minute.
The Selected Sensors Table is provided on the left side of the screen. To add a
sensor measurement to the Output Table, highlight a measurement and click
one of the output buttons; e.g., Average.
Click the
Default
sensor (battery voltage) and double click the
Minimum
button. Click the
109
temperature sensor and double click the
Average
button.
Click the
TE525
rain gauge sensor and double click the
Total
button.
Click the
Home
button to continue with Step 4 to complete the program.
Step 4: Finish
Step 4 is to finish the program. From the Home page, click the
Finish
button.
Type in CR200_QuickStart for the file name. Any errors the compiler may
have detected are displayed, along with the names of the files that were
created. The file C:\Campbellsci\SCWin\CR200_QuickStart.CR2 is the
program file that will be sent to the CR200, CR200_QuickStart.def is a
summary of the sensor wiring and measurement labels (click the
Summary
or