Section 7. Installation
239
Scan
(1,Sec,1,0)
'Measurements
'Battery Voltage
Battery
(Batt_Volt)
'Wiring Panel Temperature
PanelTemp
(PTemp_C,15000)
'Type T Thermocouple measurements:
TCDiff
(AirTemp_C,1,mV200C,U1,TypeT,PTemp_C,True,0,60,1,0)
TCDiff
(AirTemp_F,1,mV200C,U1,TypeT,PTemp_C,True,0,60,1.8,32)
'Convert from degree C to degree F
AirTemp2_F = AirTemp_C * 1.8 + 32
'Count the number of times through the program. This demonstrates the use of a
'Long integer variable in counters.
Counter = C 1
'Calculate the difference between air and panel temps
DeltaT_C = AirTemp_C - PTemp_C
'Control the flag based on the difference in temperature. If DeltaT >= 3 then
'set Flag 1 high, otherwise set it low
If
DeltaT_C >= 3
Then
Flag(1) = high
Else
Flag(1) = low
EndIf
'Turn LED connected to Port 1 on when Flag 1 is high
If
Flag(1) = high
Then
PortSet
(1,1)
'alternate syntax: PortSet(1,high)
Else
PortSet
(1,0)
'alternate syntax: PortSet(1,low)
EndIf
'Count how many times the DataEvent “DeltaT_C>=3” has occurred. The
'TableName.EventCount syntax is used to return the number of data storage events
'that have occurred for an event driven table. This example looks in the data
'table “Event”, which is declared above, and reports the event count. The (1,1)
'after EventCount just needs to be included.
HowMany = Event.EventCount(1,1)
'Call Data Tables
CallTable
(OneMin)
CallTable
(Event)
NextScan
EndProg
7.7.1.5 PulseCountReset Instruction
PulseCountReset
is used in rare instances to force the reset or zeroing of CR6
pulse accumulators. See
Measurements — Overview
(p. 71).
Summary of Contents for CR6 Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 36: ......
Page 38: ......
Page 76: ...Section 5 Overview 76 FIGURE 20 Half Bridge Wiring Example Wind Vane Potentiometer ...
Page 80: ...Section 5 Overview 80 FIGURE 23 Pulse Input Wiring Example Anemometer ...
Page 136: ......
Page 454: ...Section 8 Operation 454 FIGURE 104 Narrow Sweep High Noise ...
Page 459: ...Section 8 Operation 459 FIGURE 106 Vibrating Wire Sensor Calibration Report ...
Page 535: ...Section 8 Operation 535 8 11 2 Data Display FIGURE 121 CR1000KD Displaying Data ...
Page 537: ...Section 8 Operation 537 FIGURE 123 CR1000KD Real Time Custom ...
Page 538: ...Section 8 Operation 538 8 11 2 3 Final Storage Data FIGURE 124 CR1000KD Final Storage Data ...
Page 539: ...Section 8 Operation 539 8 11 3 Run Stop Program FIGURE 125 CR1000KD Run Stop Program ...
Page 541: ...Section 8 Operation 541 FIGURE 127 CR1000KD File Edit ...
Page 546: ......
Page 552: ......
Page 610: ...Section 11 Glossary 610 FIGURE 137 Relationships of Accuracy Precision and Resolution ...
Page 612: ......
Page 648: ......
Page 650: ......
Page 688: ......
Page 689: ......