Section 4. Quickstart
42
The CR6 is internally protected against accidental polarity reversal on the power
inputs.
4.3.1 Internal Battery — Quickstart
Related Topics:
•
Internal Battery — Quickstart
(p. 42)
•
Internal Battery — Details
(p. 547)
Warning
Misuse or improper installation of the internal lithium battery
can cause severe injury. Fire, explosion, and severe burns can result. Do
not recharge, disassemble, heat above 100 °C (212 °F), solder directly to
the cell, incinerate, or expose contents to water. Dispose of spent lithium
batteries properly.
A lithium battery backs up the CR6 clock, program, and memory.
4.3.2 Internal Voltage Regulator / Battery Charger — Quickstart
The CR6 has an internal voltage regulator and battery charger. Charge voltage is
Vdc only. It includes a thermal fused limit at 1.2 amp, which resets when the load
is removed.
BAT
terminals are for a 12 Vdc battery. Charge terminals can be
used without a battery being attached.
Power regulator:
•
Typical application: 20 W solar panel and 24 Ah 12 Vdc battery
•
Smart power management
•
Uses highest input voltage source
•
Charges using voltage temperature profile of the battery
•
5 to 24 Vdc input
BAT
terminals:
•
5 to 16.5 Vdc input or 12 Vdc battery
•
Suitable for charging sealed-rechargeable lead acid batteries only.
•
Primary power connection here has the lowest power consumption
because the regulator is bypassed.
•
Limit 2.5 A @ 12 V at 25 °C
•
Over-voltage protection
•
Reverse-polarity protection
Summary of Contents for CR6 Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 36: ......
Page 38: ......
Page 76: ...Section 5 Overview 76 FIGURE 20 Half Bridge Wiring Example Wind Vane Potentiometer ...
Page 80: ...Section 5 Overview 80 FIGURE 23 Pulse Input Wiring Example Anemometer ...
Page 136: ......
Page 454: ...Section 8 Operation 454 FIGURE 104 Narrow Sweep High Noise ...
Page 459: ...Section 8 Operation 459 FIGURE 106 Vibrating Wire Sensor Calibration Report ...
Page 535: ...Section 8 Operation 535 8 11 2 Data Display FIGURE 121 CR1000KD Displaying Data ...
Page 537: ...Section 8 Operation 537 FIGURE 123 CR1000KD Real Time Custom ...
Page 538: ...Section 8 Operation 538 8 11 2 3 Final Storage Data FIGURE 124 CR1000KD Final Storage Data ...
Page 539: ...Section 8 Operation 539 8 11 3 Run Stop Program FIGURE 125 CR1000KD Run Stop Program ...
Page 541: ...Section 8 Operation 541 FIGURE 127 CR1000KD File Edit ...
Page 546: ......
Page 552: ......
Page 610: ...Section 11 Glossary 610 FIGURE 137 Relationships of Accuracy Precision and Resolution ...
Page 612: ......
Page 648: ......
Page 650: ......
Page 688: ......
Page 689: ......