Section 8. Operation
492
CR6 SRAM Memory
Use
Comments
Static Memory
Operational memory used by the operating system. Rebuilt at power-up,
program re-compile, and watchdog events.
———————————
—
Operating Settings and
Properties
"Keep"
(p. 589)
memory. Stores settings such as PakBus address, station
name, beacon intervals, neighbor lists, etc. Also stores dynamic properties
such as the routing table, communication timeouts, etc.
———————————
—
CRBasic Program
Operating Memory
Stores the currently compiled and running user program. This sector is
rebuilt on power-up, recompile, and watchdog events.
———————————
—
Variables & Constants
Stores variables used by the CRBasic program. These values may persist
through power-up, recompile, and watchdog events if the
PreserveVariables
instruction is in the running program.
———————————
—
Final-Storage Memory
Stores data. Fills memory remaining after all other demands are satisfied.
Configurable as ring or fill-and-stop memory. Compile error occurs if
insufficient memory is available for user-allocated data tables. Given
lowest priority in SRAM memory allocation.
———————————
—
Communication Memory 1
Construction and temporary storage of PakBus packets.
———————————
—
Communication Memory 2
Constructed Routing Table: list of known nodes and routes to nodes.
Routers use more space than leaf nodes because routes to neighbors must
be remembered. Increasing the PakBusNodes field in the
Status
table will
increase this allocation.
———————————
—
USR: drive
Optionally allocated. Holds image files. Holds a copy of final-storage
memory when
TableFile()
(p. 269)
instruction used. Provides memory for
FileRead()
and
FileWrite()
operations. Managed in
File Control
(p. 503).
Status reported in
Status
table fields
USRDriveSize
(p. 640)
and
USRDriveFree
(p. 640).
Summary of Contents for CR6 Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 36: ......
Page 38: ......
Page 76: ...Section 5 Overview 76 FIGURE 20 Half Bridge Wiring Example Wind Vane Potentiometer ...
Page 80: ...Section 5 Overview 80 FIGURE 23 Pulse Input Wiring Example Anemometer ...
Page 136: ......
Page 454: ...Section 8 Operation 454 FIGURE 104 Narrow Sweep High Noise ...
Page 459: ...Section 8 Operation 459 FIGURE 106 Vibrating Wire Sensor Calibration Report ...
Page 535: ...Section 8 Operation 535 8 11 2 Data Display FIGURE 121 CR1000KD Displaying Data ...
Page 537: ...Section 8 Operation 537 FIGURE 123 CR1000KD Real Time Custom ...
Page 538: ...Section 8 Operation 538 8 11 2 3 Final Storage Data FIGURE 124 CR1000KD Final Storage Data ...
Page 539: ...Section 8 Operation 539 8 11 3 Run Stop Program FIGURE 125 CR1000KD Run Stop Program ...
Page 541: ...Section 8 Operation 541 FIGURE 127 CR1000KD File Edit ...
Page 546: ......
Page 552: ......
Page 610: ...Section 11 Glossary 610 FIGURE 137 Relationships of Accuracy Precision and Resolution ...
Page 612: ......
Page 648: ......
Page 650: ......
Page 688: ......
Page 689: ......