Section 7. Installation
176
How
Use the following procedure with
DevConfig
: Do not click
Connect
.
1. Select CR6 from the list of devices at left
2. Select the appropriate communication port and baud rate at the bottom left
3. Click the
Send OS
tab located at the top of
DevConfig
window
4. Follow the on-screen
OS Download Instructions
Pros/Cons
This is a good way to recover a CR6 that has gone into an unresponsive state.
Often, an operating system can be loaded even if you are unable to communicate
with the CR6 through other means.
Loading an operating system through this method will do the following:
1. Restore all CR6 settings to factory defaults
2. Delete data in final storage
3. Delete data from and remove the USR drive
4. Delete program files stored on the datalogger
7.5.2.2.2 OS Update with File Control
This method is very similar to sending an OS as a program, with the exception
that you have to manually prepare the datalogger to accept the new OS.
How
1. Connect to the CR6 with
Connect
or
DevConfig
2. Collect data
3. Transfer a
default.CR1
(p. 154)
program file to the CR6 CPU: drive
4. Stop the current program and select the option to delete associated data (this
will free up SRAM memory allocated for data storage)
5. Collect files from the USR: drive (if applicable)
6. Delete the USR: drive (if applicable)
7. Send the new .obj OS file to the CR6
8. Restart the previous program (default.CR1 will be running after OS compiles)
Summary of Contents for CR6 Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 36: ......
Page 38: ......
Page 76: ...Section 5 Overview 76 FIGURE 20 Half Bridge Wiring Example Wind Vane Potentiometer ...
Page 80: ...Section 5 Overview 80 FIGURE 23 Pulse Input Wiring Example Anemometer ...
Page 136: ......
Page 454: ...Section 8 Operation 454 FIGURE 104 Narrow Sweep High Noise ...
Page 459: ...Section 8 Operation 459 FIGURE 106 Vibrating Wire Sensor Calibration Report ...
Page 535: ...Section 8 Operation 535 8 11 2 Data Display FIGURE 121 CR1000KD Displaying Data ...
Page 537: ...Section 8 Operation 537 FIGURE 123 CR1000KD Real Time Custom ...
Page 538: ...Section 8 Operation 538 8 11 2 3 Final Storage Data FIGURE 124 CR1000KD Final Storage Data ...
Page 539: ...Section 8 Operation 539 8 11 3 Run Stop Program FIGURE 125 CR1000KD Run Stop Program ...
Page 541: ...Section 8 Operation 541 FIGURE 127 CR1000KD File Edit ...
Page 546: ......
Page 552: ......
Page 610: ...Section 11 Glossary 610 FIGURE 137 Relationships of Accuracy Precision and Resolution ...
Page 612: ......
Page 648: ......
Page 650: ......
Page 688: ......
Page 689: ......