Section 7. Installation
218
measurement in the variable
RefTemp
, using an fN1 of 15000, the syntax is as
shown in CRBasic example
Measurement Instruction Syntax
(p. 218).
Measurement Instruction Syntax
'This program example demonstrates the use of a single measurement instruction. In this
'case, the program measures the temperature of the CR6 wiring panel.
Public RefTemp
'Declare variable to receive instruction
BeginProg
Scan
(1,Sec,3,0)
PanelTemp
(RefTemp, 15000)
'<<<<<<Instruction to make measurement
NextScan
EndProg
7.6.3.14.2 Argument Types
Most CRBasic commands (
instructions
) have sub-commands (
parameters
).
Parameters are populated by the programmer with arguments. Many instructions
have parameters that allow different types of arguments. Common argument types
are listed below. Allowed argument types are specifically identified in the
description of each instruction in
CRBasic Editor Help
.
•
Constant, or expression that evaluates as a constant
•
Variable
•
Variable or array
•
Constant, variable, or expression
•
Constant, variable, array, or expression
•
Name
•
Name or list of names
•
Variable, or expression
•
Variable, array, or expression
7.6.3.14.3 Names in Arguments
Table
Rules for Names
(p. 219)
lists the maximum length and allowed characters for
the names for variables, arrays, constants, etc. The
CRBasic Editor
pre-compiler
will identify names that are too long or improperly formatted.
Caution
Concerning characters allowed in names, characters not listed
in in the table,
Rules for Names
, may appear to be supported in a specific
operating system. However, they may not be supported in future
operating systems.
Summary of Contents for CR6 Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 36: ......
Page 38: ......
Page 76: ...Section 5 Overview 76 FIGURE 20 Half Bridge Wiring Example Wind Vane Potentiometer ...
Page 80: ...Section 5 Overview 80 FIGURE 23 Pulse Input Wiring Example Anemometer ...
Page 136: ......
Page 454: ...Section 8 Operation 454 FIGURE 104 Narrow Sweep High Noise ...
Page 459: ...Section 8 Operation 459 FIGURE 106 Vibrating Wire Sensor Calibration Report ...
Page 535: ...Section 8 Operation 535 8 11 2 Data Display FIGURE 121 CR1000KD Displaying Data ...
Page 537: ...Section 8 Operation 537 FIGURE 123 CR1000KD Real Time Custom ...
Page 538: ...Section 8 Operation 538 8 11 2 3 Final Storage Data FIGURE 124 CR1000KD Final Storage Data ...
Page 539: ...Section 8 Operation 539 8 11 3 Run Stop Program FIGURE 125 CR1000KD Run Stop Program ...
Page 541: ...Section 8 Operation 541 FIGURE 127 CR1000KD File Edit ...
Page 546: ......
Page 552: ......
Page 610: ...Section 11 Glossary 610 FIGURE 137 Relationships of Accuracy Precision and Resolution ...
Page 612: ......
Page 648: ......
Page 650: ......
Page 688: ......
Page 689: ......