Section 8. Operation
479
8.4.4 Pulse Input Modules
Read More
For more information see
Pulse Input Modules — List
(p. 652).
Pulse input expansion modules are available for switch-closure, state, pulse count
and frequency measurements, and interval timing.
8.4.4.1 Low-Level Ac Input Modules — Overview
Related Topics:
•
Low-Level Ac Input Modules — Overview
(p. 479)
•
Low-Level Ac Measurements — Details
(p. 441)
•
Pulse Input Modules — List
(p. 652)
Low-level ac input modules increase the number of low-level ac signals a CR6
can monitor by converting low-level ac to high-frequency pulse.
8.4.5 Serial I/O Modules — Details
Read More
For more information see appendix
Serial I/O Modules List
(p.
Capturing input from intelligent serial-output devices can be challenging. Several
Campbell Scientific serial I/O modules are designed to facilitate reading and
parsing serial data.
8.4.6 Terminal-Input Modules
Read More
See
Passive Signal Conditioners — List
(p. 653).
Terminal Input Modules (TIMs) are devices that provide simple
measurement-support circuits in a convenient package. TIMs include voltage
dividers for cutting the output voltage of sensors to voltage levels compatible with
the CR6, modules for completion of resistive bridges, and shunt modules for
measurement of analog-current sensors.
8.4.7 Vibrating Wire Modules
Read More
For complete information, see
Vibrating Wire Modules — List
(p. 653).
The CR6 measures vibrating wire sensors directly (see
Vibrating Wire
Measurements — Overview
. Its input capacity can be expanded through use
of vibrating wire modules.
Summary of Contents for CR6 Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 36: ......
Page 38: ......
Page 76: ...Section 5 Overview 76 FIGURE 20 Half Bridge Wiring Example Wind Vane Potentiometer ...
Page 80: ...Section 5 Overview 80 FIGURE 23 Pulse Input Wiring Example Anemometer ...
Page 136: ......
Page 454: ...Section 8 Operation 454 FIGURE 104 Narrow Sweep High Noise ...
Page 459: ...Section 8 Operation 459 FIGURE 106 Vibrating Wire Sensor Calibration Report ...
Page 535: ...Section 8 Operation 535 8 11 2 Data Display FIGURE 121 CR1000KD Displaying Data ...
Page 537: ...Section 8 Operation 537 FIGURE 123 CR1000KD Real Time Custom ...
Page 538: ...Section 8 Operation 538 8 11 2 3 Final Storage Data FIGURE 124 CR1000KD Final Storage Data ...
Page 539: ...Section 8 Operation 539 8 11 3 Run Stop Program FIGURE 125 CR1000KD Run Stop Program ...
Page 541: ...Section 8 Operation 541 FIGURE 127 CR1000KD File Edit ...
Page 546: ......
Page 552: ......
Page 610: ...Section 11 Glossary 610 FIGURE 137 Relationships of Accuracy Precision and Resolution ...
Page 612: ......
Page 648: ......
Page 650: ......
Page 688: ......
Page 689: ......