Appendix A. Info Tables and Settings
630
IPGateway
String
•
Settings Editor:
Ethernet | IP Gateway
Specifies the address of the IP router to which the CR6 will forward all non-local IP packets
for which it has no route. A change will cause the CRBasic program to recompile.
IPGateway
CSIO()
String
•
Settings Editor:
CS I/O IP | Gateway
•
Specifies the gateway for CS I/O. A change will cause the CRBasic program to
recompile.
IPGatewayWiFi
String
•
Settings Editor:
Wi-Fi | IP Gateway
Specifies the gateway for the WiFi Ethernet interface. This setting is made available only if
the WiFi module is in the CR6. A change will cause the CRBasic program to recompile.
IPInfo
1
String
•
Settings Editor:
Ethernet | {information box}
Indicates current parameters for IP connection. IPInfo is a status field but the CR6 processes
it as a setting to minimize bandwidth. It requires about 1.5 KB when all IP interfaces are
active. This 1.5 KB is transfered each time it is requested regardless of how many IP
interfaces are actually used. See
IPInfo()
CRBasic instruction. Updates when status is
queried.
IPMaskCSIO()
String
•
Settings Editor:
CS I/O IP | Subnet Mask
IPMaskEth
String
•
Settings Editor:
Ethernet | Subnet Mask
Specifies the subnet mask for the Ethernet interface. This setting is made available when an
Ethernet link is connected. A change will cause the CRBasic program to recompile.
IPMaskEthWiFi
String
•
Settings Editor:
WiFi | Subnet Mask
Specifies the subnet mask for the WiFi Ethernet interface. This setting is made available
only if the WiFi module is in the CR6. A change will cause the CRBasic program to
recompile.
IPTrace
Discontinued; aliased to
IPTraceComport
IPTraceCode
UINT2
•
Settings Editor:
Advanced | IP Trace Code
Controls what type of information is sent on the port specified by
IPTraceComport
and via
Telnet. Default =
0
.
IPTraceComport
Numeric
•
Settings Editor:
Advanced | IP Trace COM Port
Specifies the port (if any) on which TCP/IP trace information is sent. Information type is
controlled by
IPTraceCode
. Default is
0
= inactive.
IsRouter
Numeric
•
Settings Editor:
Advanced | Is Router
Controls configuration of CR6 as a router or leaf node.
True
= router.
False
(default) = leaf
node.
IxResistor
Numeric Y
•
Status
table field: ≈51
Factory-calibrated correction factor (ohms) applied to resistance measurements. Normal
value is near 1000 ohms. Updates at start up.
Summary of Contents for CR6 Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 36: ......
Page 38: ......
Page 76: ...Section 5 Overview 76 FIGURE 20 Half Bridge Wiring Example Wind Vane Potentiometer ...
Page 80: ...Section 5 Overview 80 FIGURE 23 Pulse Input Wiring Example Anemometer ...
Page 136: ......
Page 454: ...Section 8 Operation 454 FIGURE 104 Narrow Sweep High Noise ...
Page 459: ...Section 8 Operation 459 FIGURE 106 Vibrating Wire Sensor Calibration Report ...
Page 535: ...Section 8 Operation 535 8 11 2 Data Display FIGURE 121 CR1000KD Displaying Data ...
Page 537: ...Section 8 Operation 537 FIGURE 123 CR1000KD Real Time Custom ...
Page 538: ...Section 8 Operation 538 8 11 2 3 Final Storage Data FIGURE 124 CR1000KD Final Storage Data ...
Page 539: ...Section 8 Operation 539 8 11 3 Run Stop Program FIGURE 125 CR1000KD Run Stop Program ...
Page 541: ...Section 8 Operation 541 FIGURE 127 CR1000KD File Edit ...
Page 546: ......
Page 552: ......
Page 610: ...Section 11 Glossary 610 FIGURE 137 Relationships of Accuracy Precision and Resolution ...
Page 612: ......
Page 648: ......
Page 650: ......
Page 688: ......
Page 689: ......