Appendix A. Info Tables and Settings
638
SkippedScan
Numeric Y
•
Station Status field:
Skipped Scans
•
Status
table field: ≈22
Number of
skipped program scans
(p. 562)
that have occurred while running the CRBasic
program. Does not include scans intentionally skipped as may occur with the use of
ExitScan
and
Do
/
Loop
instructions. Updated when they occur.
SkippedSlow
Scan()
Numeric Y
•
Station Status field:
Skipped Slow Scans
•
Status
table field: ≈24
Number of skipped scans for each
SlowSequence
scan in the CRBasic program. See
LastSlowScan
(p. 631),
MaxSlowProcTime
(p. 632),
SlowProcTime
(p. 638).
Skipped
SystemScan()
Numeric Y
•
Station Status field:
Skipped System Scans
•
Status
table field: ≈23
Number of scans skipped in the auto (background) calibration. Enter 0 to reset. See
LastSystemScan
(p. 631),
MaxSystemProcTime
(p. 632),
and
SystemProcTime
(p. 638).
SlowProcTime()
Numeric Y
•
Status
table field: ≈39
Time (μs) required to process a
SlowSequence
scan. See
LastSlowScan
(p. 631),
MaxSlowProcTime
(p. 632),
SkippedSlowScan
(p. 638).
Default is a large number until a
SlowSequence
runs.
StartTime
NSEC
Y
•
Station Status field:
Start Time
•
Status
table field: 8
Time (date and time) the CRBasic program started. Updates at beginning of program
compile.
StartUpCode
Numeric Y
•
Status
table field: ≈19
Indicates how the running program was compiled.
True
: program compiled by CR6 starting
from a power-down condition.
False
: program compiled by either a
Program Send
, a
File
Control
transaction, or a watchdog reset. Updated at startup.
StationName
String
•
Station Status field:
Reported Station Name
•
Settings Editor:
Datalogger | Station Name
•
Status
table field: 6
Station name stored in flash memory. This is not the same name as that is entered into
LoggerNet
. This station name can be sampled into a data table, but it is not the name that
appears in data file headers. Updated at startup or when the name is changed.
SW12Volts()
Numeric
•
Status
table field: ≈44
Status of switched, 12 Vdc terminal.
True
= on. Updates when the state changes.
SystemProcTime
FLOAT
Y
•
Status
table field: ≈37
Time (μs)
required to process auto (background) calibration. Default is a large number until
auto self-calibration runs.
Summary of Contents for CR6 Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 36: ......
Page 38: ......
Page 76: ...Section 5 Overview 76 FIGURE 20 Half Bridge Wiring Example Wind Vane Potentiometer ...
Page 80: ...Section 5 Overview 80 FIGURE 23 Pulse Input Wiring Example Anemometer ...
Page 136: ......
Page 454: ...Section 8 Operation 454 FIGURE 104 Narrow Sweep High Noise ...
Page 459: ...Section 8 Operation 459 FIGURE 106 Vibrating Wire Sensor Calibration Report ...
Page 535: ...Section 8 Operation 535 8 11 2 Data Display FIGURE 121 CR1000KD Displaying Data ...
Page 537: ...Section 8 Operation 537 FIGURE 123 CR1000KD Real Time Custom ...
Page 538: ...Section 8 Operation 538 8 11 2 3 Final Storage Data FIGURE 124 CR1000KD Final Storage Data ...
Page 539: ...Section 8 Operation 539 8 11 3 Run Stop Program FIGURE 125 CR1000KD Run Stop Program ...
Page 541: ...Section 8 Operation 541 FIGURE 127 CR1000KD File Edit ...
Page 546: ......
Page 552: ......
Page 610: ...Section 11 Glossary 610 FIGURE 137 Relationships of Accuracy Precision and Resolution ...
Page 612: ......
Page 648: ......
Page 650: ......
Page 688: ......
Page 689: ......