651
Appendix E. Supporting Products — List
Supporting products power and expand the measurement and control capability of
the CR6. Products listed are manufactured by a Campbell Scientific group
company unless otherwise noted. Consult product literature at
www.campbellsci.com
or a Campbell Scientific sales engineer to determine what
products are most suited to particular applications. The following listings are not
exhaustive, but are current as of the manual publication date.
E.1 Dataloggers — List
Related Topics:
•
Datalogger — Quickstart
(p. 40)
•
Datalogger — Overview
(p. 60)
•
Dataloggers — List
(p. 651)
Other Campbell Scientific datalogging devices can be used in networks with the
CR6. Data and control signals can pass from device to device with the CR6 acting
as a master, peer, or slave. Dataloggers communicate in a network via PakBus
®
,
Modbus, DNP3, RS-232, SDI-12, or CANbus using the SDM-CAN module.
Dataloggers
Model
Description
CR200X Series
Dataloggers
Limited input, not expandable.
Suited for a network of stations with a
small numbers of specific inputs.
Some models have built-in radio
transceivers for spread-spectrum
communication and various frequency
bands.
CR800-Series
Dataloggers
Limited input, but expandable.
Suited for a network of stations with
small numbers of specific inputs.
The CR850 has a built-in keyboard
and display.
CR6
Measurement and Control Datalogger
12 universal input terminals accept
analog or pulse inputs. 4 I/O
terminals are configurable for control
or multiple communication protocols.
This instrument is very versatile,
expandable, and networkable.
CR1000
Measurement and Control System
16 analog input terminals, two pulse
input terminals, eight control / I/O
terminals. Expandable.
Summary of Contents for CR6 Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 36: ......
Page 38: ......
Page 76: ...Section 5 Overview 76 FIGURE 20 Half Bridge Wiring Example Wind Vane Potentiometer ...
Page 80: ...Section 5 Overview 80 FIGURE 23 Pulse Input Wiring Example Anemometer ...
Page 136: ......
Page 454: ...Section 8 Operation 454 FIGURE 104 Narrow Sweep High Noise ...
Page 459: ...Section 8 Operation 459 FIGURE 106 Vibrating Wire Sensor Calibration Report ...
Page 535: ...Section 8 Operation 535 8 11 2 Data Display FIGURE 121 CR1000KD Displaying Data ...
Page 537: ...Section 8 Operation 537 FIGURE 123 CR1000KD Real Time Custom ...
Page 538: ...Section 8 Operation 538 8 11 2 3 Final Storage Data FIGURE 124 CR1000KD Final Storage Data ...
Page 539: ...Section 8 Operation 539 8 11 3 Run Stop Program FIGURE 125 CR1000KD Run Stop Program ...
Page 541: ...Section 8 Operation 541 FIGURE 127 CR1000KD File Edit ...
Page 546: ......
Page 552: ......
Page 610: ...Section 11 Glossary 610 FIGURE 137 Relationships of Accuracy Precision and Resolution ...
Page 612: ......
Page 648: ......
Page 650: ......
Page 688: ......
Page 689: ......