Section 5. Overview
71
•
G
Power ground return for
SW12
,
12V
terminals, current loop sensors,
and
U
or
C
configured for control. Use of
G
grounds for these outputs
minimizes potentially large current flow through the
analog-voltage-measurement section of the wiring panel, which can
cause single-ended voltage measurement errors.
•
RG
Resistive ground return for RS-485 connections.
•
Earth ground lug connection point for a heavy-gage earth-ground
wire. A good earth connection is necessary to secure the ground potential
of the CR6 and shunt transients away from electronics. Minimum 14
AWG wire is recommended.
5.2
Measurements — Overview
Related Topics:
•
Sensors — Quickstart
(p. 39)
•
Measurements — Overview
(p. 71)
•
Measurements — Details
(p. 387)
•
Sensors — Lists
(p. 657)
Most electronic sensors, whether or not they are supplied by Campbell Scientific,
can be connected directly to the CR6.
Manuals that discuss alternative input routes, such as external multiplexers,
peripheral measurement devices, or a wireless sensor network, can be found at
www.campbellsci.com/manuals
.
This section discusses direct sensor-to-datalogger connections and applicable
CRBasic programming to instruct the CR6 how to make, process, and store the
measurements. Terminals on the CR6 wiring panel, as described in table
CR6
Terminal Definitions
(p. 62),
are configurable for the measurements discussed in the
following sections:
5.2.1 Time Keeping — Overview
Related Topics:
•
Time Keeping — Overview
(p. 71)
•
Time Keeping — Details
(p. 387)
Measurement of time is an essential function of the CR6. Time measurement with
the on-board clock enables the CR6 to attach time stamps to data, measure the
interval between events, and time the initiation of control functions.
5.2.2 Analog Measurements — Overview
Related Topics:
•
Analog Measurements — Overview
(p. 71)
•
Analog Measurements — Details
(p. 389)
Summary of Contents for CR6 Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 36: ......
Page 38: ......
Page 76: ...Section 5 Overview 76 FIGURE 20 Half Bridge Wiring Example Wind Vane Potentiometer ...
Page 80: ...Section 5 Overview 80 FIGURE 23 Pulse Input Wiring Example Anemometer ...
Page 136: ......
Page 454: ...Section 8 Operation 454 FIGURE 104 Narrow Sweep High Noise ...
Page 459: ...Section 8 Operation 459 FIGURE 106 Vibrating Wire Sensor Calibration Report ...
Page 535: ...Section 8 Operation 535 8 11 2 Data Display FIGURE 121 CR1000KD Displaying Data ...
Page 537: ...Section 8 Operation 537 FIGURE 123 CR1000KD Real Time Custom ...
Page 538: ...Section 8 Operation 538 8 11 2 3 Final Storage Data FIGURE 124 CR1000KD Final Storage Data ...
Page 539: ...Section 8 Operation 539 8 11 3 Run Stop Program FIGURE 125 CR1000KD Run Stop Program ...
Page 541: ...Section 8 Operation 541 FIGURE 127 CR1000KD File Edit ...
Page 546: ......
Page 552: ......
Page 610: ...Section 11 Glossary 610 FIGURE 137 Relationships of Accuracy Precision and Resolution ...
Page 612: ......
Page 648: ......
Page 650: ......
Page 688: ......
Page 689: ......