10.1 Troubleshooting — Essential Tools
•
Multimeter (combination volt meter and resistance meter). Inexpensive
($20.00) meters are useful. The more expensive meters have additional
modes of operation that are useful in some situations.
•
Cell or satellite phone with contact information for Campbell Scientific
support engineers. Establish a current contact at Campbell Scientific
before going to the field. A support engineer may be able to provide
you with information that will better prepare you for the field visit.
•
Product documentation in a reliable format and easily readable at the
installation site. Sun glare, dust, and moisture often make electronic
media difficult to use and unreliable.
10.2 Troubleshooting — Basic Procedure
1. Check the voltage of the primary power source at the
POWER IN
terminals
on the face of the CR800.
2. Check wires and cables for the following:
o
Loose connection points
o
Faulty connectors
o
Cut wires
o
Damaged insulation, which allows water to migrate into the cable.
Water, whether or not it comes in contact with wire, can cause
system failure. Water may increase the dielectric constant of the
cable sufficiently to imped sensor signals, or it may migrate into the
sensor, which will damage sensor electronics.
3. Check the CRBasic program. If the program was written solely with
Short
Cut
, the program is probably not the source of the problem. If the program was
written or edited with
CRBasic Editor
, logic and syntax errors could easily
have crept into the code. To troubleshoot, create a stripped down version of
the program, or break it up into multiple smaller units to test individually. For
Summary of Contents for CR800 Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 34: ......
Page 54: ......
Page 92: ......
Page 310: ......
Page 446: ...Section 8 Operation 446 8 11 2 Data Display FIGURE 100 CR1000KD Displaying Data ...
Page 448: ...Section 8 Operation 448 FIGURE 102 CR1000KD Real Time Custom ...
Page 449: ...Section 8 Operation 449 8 11 2 3 Final Storage Data FIGURE 103 CR1000KD Final Storage Data ...
Page 450: ...Section 8 Operation 450 8 11 3 Run Stop Program FIGURE 104 CR1000KD Run Stop Program ...
Page 452: ...Section 8 Operation 452 FIGURE 106 CR1000KD File Edit ...
Page 456: ......
Page 462: ......
Page 523: ...Section 11 Glossary 523 FIGURE 116 Relationships of Accuracy Precision and Resolution ...
Page 524: ......
Page 526: ......
Page 556: ......
Page 558: ......
Page 560: ......
Page 597: ......