Section 10. Troubleshooting
482
10.9.3.4 Adjusting Charging Voltage
Note
Campbell Scientific recommends that a qualified electronic
technician perform the following procedure.
The procedure outlined in this flow chart tests and adjusts PS100 and CH100
charging regulators. If a need for repair or calibration is indicated after following
the procedure, see
Assistance
for information on sending items to Campbell
Scientific.
Adjusting Charging Circuit
1) Place a 5 kΩ resistor between a
12V
terminal and a
G
(ground) ground terminal
on the charging regulator. Us
e a voltmeter to measure the voltage across the 5 kΩ
resistor.
2) Connect a power source that supplies a voltage >17 V to the input
CHG
terminals
of the charging regulator.
3) Adjust pot R3 (see
FIGURE: Potentiometer R3 on PS100 and CH100 Charging
Regulators
(p. 483)
) so that voltage across the 5 kΩ resistor is 13.3 Vdc.
Can the output voltage be set to 13.3 V?
No
Yes
50 Ω Load Test
1) Switch the power switch to
OFF
.
2) Disconnect the power source (transformer / solar panel).
3) Remove the 5 kΩ resistor
4) Place a 50 Ω, 1 W resistor between a
12V
terminal and a
G
(ground) terminal on
the charging regulator.
5) Reconnect the power source and then switch the power switch to
ON
.
7) Measure the voltage across the ends of the resistor.
Is the voltage 13.0 to 14.0 Vdc (13.3 if circuit just adjusted)?
8) Switch the power switch to
OFF
.
NOTE
The resistor will get HOT in just a few seconds. After measuring the voltage,
switch the power switch to
OFF
and allow the resistor to cool before removing it.
Get Repair Authorization
The charging regulator is damaged and should be repaired
or replaced.
No
Yes
Test Completed
The charger is functioning properly. Remove the 50 Ω resistor.
Summary of Contents for CR800 Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 34: ......
Page 54: ......
Page 92: ......
Page 310: ......
Page 446: ...Section 8 Operation 446 8 11 2 Data Display FIGURE 100 CR1000KD Displaying Data ...
Page 448: ...Section 8 Operation 448 FIGURE 102 CR1000KD Real Time Custom ...
Page 449: ...Section 8 Operation 449 8 11 2 3 Final Storage Data FIGURE 103 CR1000KD Final Storage Data ...
Page 450: ...Section 8 Operation 450 8 11 3 Run Stop Program FIGURE 104 CR1000KD Run Stop Program ...
Page 452: ...Section 8 Operation 452 FIGURE 106 CR1000KD File Edit ...
Page 456: ......
Page 462: ......
Page 523: ...Section 11 Glossary 523 FIGURE 116 Relationships of Accuracy Precision and Resolution ...
Page 524: ......
Page 526: ......
Page 556: ......
Page 558: ......
Page 560: ......
Page 597: ......