background image

INSTRUCTION MANUAL

CS500-LC Temperature and

Relative Humidity Probe

for MetData1

4/97

C o p y r i g h t   ( c )   1 9 9 5 - 1 9 9 7

C a m p b e l l   S c i e n t i f i c ,   I n c .

Summary of Contents for CS500-LC

Page 1: ...INSTRUCTION MANUAL CS500 LC Temperature and Relative Humidity Probe for MetData1 4 97 C o p y r i g h t c 1 9 9 5 1 9 9 7 C a m p b e l l S c i e n t i f i c I n c ...

Page 2: ...is in lieu of all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequential damages Products may not be returned without prior authorization The following contact information is for US and International customers residing in countries served by Campbell Sci...

Page 3: ...cally 2 mA Diameter 0 47 inches 12 mm Length 2 66 inches 68 mm Housing Material ABS Plastic 2 INSTALLATION The CS500 must be housed inside a solar radiation shield when used in the field The 41301 6 Plate Radiation Shield see Figure 1 mounts to a CM6 CM10 tripod The CS500 is held within the 41301 with a mounting clamp See Figure 2 The 41002 12 Plate Radiation Shield see Figure 3 mounts to a CM6 CM...

Page 4: ...is measured by two single ended voltage instructions Instruction 1 The multiplier and offset for temperature in degrees Celsius is 0 1 and 40 respectively The multiplier and offset for temperature in degrees Fahrenheit is 0 18 and 40 respectively The multiplier and offset for relative humidity is 0 1 and 0 respectively Instruction 86 sets control port 1 high Control port 1 turns on the 12 V switch...

Page 5: ... s end should also be cleared of dust and debris When installed in close proximity to the ocean or other bodies of salt water e g Great Salt Lake a coating of salt mostly NaCl may build up on the radiation shield sensor filter and even the chip NaCl has an affinity for water The humidity over a saturated NaCl solution is 75 A buildup of salt on the filter or chip will delay or destroy the response...

Page 6: ...CS500 LC TEMPERATURE AND RELATIVE HUMIDITY PROBE FOR METDATA1 4 This is a blank page ...

Page 7: ...This is a blank page ...

Page 8: ... campbellsci com br suporte campbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Ltd CSL Campbell Park 80 Hathern Road Shepshed Loughborough LE12 9GX UNITED KINGDOM www campbellsci co uk sales campbellsci co uk Campbell Scientific Ltd France Miniparc du Verger Bat H 1 rue de Te...

Reviews: