CSAT3B Three-Dimensional Sonic Anemometer
33
The appropriate port and cable type to be used are determined by the chosen
communication method. TABLE
shows some of the criteria to use when
determining the best communication method for a given application. Once a
suitable method is determined, the appropriate combination of cables,
connectors, and lengths should be used (see Section
(p. 11)
, for information about ordering cables).
If the CSAT3B is going to be operated using SDM or CPI communications
where the data logger triggers the measurement and the data are unfiltered (see
(p. 48)
), then the CSAT3B default
settings are appropriate and do not require modification. If, however, the
CSAT3B will be operated in another mode that either requires data filters or
uses USB or RS-485 communications, the settings must be modifying as
(p. 23)
Unlike previous CSAT3 models, the CSAT3B does not include
7.6 m (25 ft) lengths of all cable types. Only the 5 m (16 ft) USB
cable for initial configuration of the sensor is included. Other
cables must be ordered separately.
TABLE 7-2. Summary of Communications Options for the CSAT3B
SDM
USB
CPI
RS-485
Data collection
Data loggers:
• CR6
• CR800
• CR1000X
• CR3000
Computer
Data loggers:
• CR6
• CR800
1/
• CR1000X
1/
• CR3000
1/
Computer
Cable length
Medium
Short, < 5 m
Longest
Long
Required cables
CSAT3BCBL1
CSAT3BCBL2 and
USB cable (included)
CSAT3BCBL2 and
CSAT3BCBL3
CSAT3BCBL2 and
CSAT3BCBL3
Robustness
Better
Worse
Best
Better
Bandwidth
OK
Best
Best
OK
Synchronization
with other sensors
Best
Worse
Best
Worse
Noisy environments
OK
OK
Best
Better
1/
Requires using the SC-CPI Interface
CPI communications is preferred over SDM communications
when using a CR6 or CR1000X data logger. See TABLE
examine the suitability of communications type based on various
parameters for other combinations.
7.7 Communications
There are many possible configurations of multiple CSAT3Bs and other
sensors on a single measurement station or system. Accordingly, power
requirements and sensor cable lengths should be taken into account to
NOTE
NOTE