CSAT3B Three-Dimensional Sonic Anemometer
2
The CSAT3B ships with:
•
CM250 leveling mounting kit
•
USB data cable
•
Certificate of conformance
4. QuickStart
This QuickStart section covers only the very basic steps in setting up a
CSAT3B using SDM or CPI communications with a Campbell Scientific data
logger. It is intended primarily as an overview and general reference for setup
of a CSAT3B, and is not intended as a replacement for the more detailed
information on installation found in Section
(p. 22)
.
4.1 Hardware Connections
1.
Mount a 3.33 cm (1.31 in) outer diameter pipe or crossarm (such as a
CM20X) to a tripod mast or tower as shown in FIGURE
FIGURE 4-1. Mounting a CM20X crossarm with crossarm-to-pole
bracket
2.
Mount the CM250 leveling mount to the end of the crossarm as shown in
3.
Use the captive bolt on the CM250 to mount the CSAT3B (FIGURE
).
The orientation of the CSAT3B should be level and pointing in the
direction of the prevailing wind.
Crossarm-to-Pole
Bracket
CM20X Crossarm