CSIOPCServer
5.
comm disabled - Communications for this device, one of its parents,
or for the whole network is disabled.
6.
invalid table defs - Collection for this station is disabled until the
table definitions are refreshed.
7.
network paused - Automated operations are paused for the network
either because the scheduledOn setting is turned off or because the
server application DLL (coralib3.dll and newer) has not yet been
enabled for automation.
8.
unreachable – The device cannot be reached through the network.
6.3.2.15 Vals Last Coll
Type:
uint4
Applies to:
21X, CR7X, CR10, CR10X, CR500, CR510, CR23X, CR10T,
CR10X-TD, CR510T, CR23X-TD, CR9000, CR5000, CR10X-PB,
CR510-PB, CR23X-PB, CR205, CR210, CR215, CR1000
Description:
The number of scalar values that have been collected from the
datalogger since the last poll began.
6.3.2.16 Vals to Coll
Type:
uint4
Applies to:
21X, CR7X, CR10, CR10X, CR500, CR510, CR23X, CR10T,
CR10X-TD, CR510T, CR23XTD, CR9000, CR5000, CR10X-PB,
CR510-PB, CR23X-PB, CR200 Series, CR800, CR1000, CR3000
Description:
The number of scalar values that are/were expected in the current
or last poll.
6.3.2.17 Values in Holes
Type:
uint4
Applies to:
CR10T, CR10X-TD, CR510T, CR23X-TD
Description:
The number of values in holes that need to be collected from the
datalogger.
6.3.2.18 Uncoll Holes
Type:
uint4
Applies to:
CR10T, CR10X-TD, CR510T, CR23X-TD
Description:
The total number of values that have been in uncollectable holes
since the device was started or the statistic was reset.
11