Appendix Title
14
9.3
Connection via CS I/O Ports
FIGURE 9-1. Modem connection to data logger CS I/O port
TABLE 9-2. Parts Supplied with CS I/O Modem Kit
Part number
Description
14162
Enclosure mounting kit for modem
CSIO-INTELIMAX-CBL
DCE RS-232 female to RJ45 cable
MA-2015
Intelimax modem
SC932A
RS-232 to CS I/O converter
ANT-ADAPTER-INTELIMAX
FME to SMA adaptor
To connect a new CS I/O modem kit to a data logger, follow these steps:
Connect the CSIO-INTELIMAX-CBL’s RJ45 connector to the socket on the
modem.
Connect the two tinned wires on this cable to the data logger. The red wire
connects to 12V and the black wire to the G terminal. The SW12 terminal can
be used instead of 12V however as it is a switched supply it needs to be
enabled in the datalogger program to function correctly.