4. Place the enclosure at the desired height. Please note that the recommended cable lengths
for the sensors assume the bottom of the enclosure is mounted 1 m (3 ft) from the ground.
5. Insert the tab on the end of the screw threads (
(p. 23)) into the hole at one
end of the upper strap.
FIGURE 6-20. Securing the enclosure to a pole
6. Pull the strap tight around the pole to determine which hole to insert the screw clamp at
the other end of the strap. Insert the clamp into this hole.
7. Use metal shears to remove any excess strap, leaving a small amount for adjustments.
8. Insert the screw threads into the screw clamp and tighten, using a flathead screwdriver or
nut driver.
9. Repeat steps 5–8 for the lower strap.
10. Ensure the enclosure is properly grounded through the use of a ground rod or similar
device.
Enclosures
23