LS300G-EU GSM/GPRS/EDGE/HSPA+ Sierra Wireless Cellular Modem
4
On the
Settings
tab:
Set the
RS-232 Baud Rate
appropriate to the datalogger being used:
o
115.2K
for CR800 Series, CR1000, CR3000, and CR6 Series
o
9600
for all others
Enter
I2GOLD
(or your custom APN) in the
APN
field.
Note that the default
Device Port
number is
3001
. This is used in the
LoggerNet
setup below.
Click
Apply
to save the settings. Reset the modem by briefly pressing the
Reset
button on the front of the modem or by removing power from the modem.