NL110 NTCIP Interface
9
TcpSer - This option configures the NL100 to act as a TCP/IP based serial
server when communicating with a datalogger over its RS-232 port.
RS-232 bps - This is the bits per second (bps) at which the NL110 will
communicate using the RS-232 port. This is a fixed rate (i.e., it is not a
maximum baud rate or an autobaud rate). Note that the CR10X-2M can
communicate at a maximum baud rate of 9600 bps, so to communicate
with one of those dataloggers, this setting must be 9600 bps or less. The
default setting is 115K bps.
RS-232 serial server port number - Enter the port number, in the range of
1 to 65000, that will be used for communication. The default port number
is 6784.
PakSer - The RS-232 port of the NL110 can be configured as a PakBus serial
server. This sets up the device as a serial server. In this mode, PakBus framing
is removed from the packet and routed via the RS-232 port.
RS-232 bps - This is the bits per second (bps) at which the NL110 will
communicate using the RS-232 port. This is a fixed rate (i.e., it is not a
maximum baud rate or an autobaud rate). Note that the CR10X-2M and
the CR510 can communicate at a maximum baud rate of 9600 bps, so to
communicate with one of those dataloggers, this setting must be 9600 bps
or less. The default setting is 115K bps.
RS-232 Serial Server AppId number - Enter the application ID, in the
range of 1 to 65000, that will be used to identify the PakSer in the
network. The default ID is 6784.
ConfMon - Configuring the RS-232 port as a ConfMon allows you to connect
directly to the NL110 via a computer and null modem. There are no
parameters; the baud rate is automatically set to 115,200 bps. Refer to Section
3.2.1 for additional information.
2.3.3.5 Ethernet 10 Base-T
EtherNet 10BASE-T (enabled, disabled) [enabled]:
10BASE-T port IP address [192.168.7.53]:
10BASE-T port network mask [255.255.255.0]:
Is there a default gatway (yes, no) [no]:
The 10 Base-T communications link is used to connect the NL110 to a TCP/IP
network using a Category 5 twisted pair cable. The Ethernet 10 Base-T link
must be configured, or you will not be able to communicate with the NL110
over a TCP/IP connection. The following options must be configured. These
values should be provided by your network administrator.
10BASE-T Port IP Address - This number is the address of the NL110 on
a TCP/IP network. It is written as 32-bit number written in four 8-bit
decimal-equivalent syllables separated by periods, in the format
Summary of Contents for NL110
Page 4: ...This is a blank page...
Page 18: ...NL110 NTCIP Interface 14 This is a blank page...
Page 20: ...This is a blank page...
Page 22: ...This is a blank page...
Page 24: ...This is a blank page...
Page 28: ...This is a blank page...
Page 29: ...This is a blank page...