A-1

Appendix A.  CS I/O Port

The CS I/O port is Campbell Scientific's input/output port.  It is not a standard
RS-232 pin-out.  The following table provides pin-out information on the port
when connected to a datalogger.

Pin

Name

Signal
Type

Description

1

5 V (supplied by the
datalogger)

Input

Not used by NL1110

2

Signal Ground

Provides reference for voltage
levels

3

Ring

Output

Raised by a NL110 to put the
datalogger into the
telecommunications mode

4

RXD

Output

Serial data transmitted to the
datalogger

5

Modem Enable

Input

Raised by the datalogger when
it determines that the NL110
raised the ring line

6

Synchronous Device
Enable

Input

Used by the datalogger to
address the NL110 when the
NL110 is configured as a
synchronous device

7

Clock/Handshake

Input

Used by the datalogger with
SDE and TXD lines to address
and transfer data to
synchronous devices

8

12 V (supplied by the
datalogger)

Not used by the NL110

9

TXD

Input

Serial data received from the
datalogger

Summary of Contents for NL110

Page 1: ...INSTRUCTION MANUAL NL110 NTCIP Interface 4 05 C o p y r i g h t c 2 0 0 0 2 0 0 5 C a m p b e l l S c i e n t i f i c I n c...

Page 2: ...other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequential...

Page 3: ...Physical Connection 3 2 2 Communication with the NL110 4 2 2 1 Establishing the Initial Communication 4 2 2 2 Establishing Communication Outside of ConfMon Mode 4 2 3 NL110 Menu Options 5 2 3 1 Ver 6...

Page 4: ...This is a blank page...

Page 5: ...ation The NL110 has an operating system that communicates with standard SNPM communication The data collected from the logger is NTCIP compliant and is collected when an incoming call requests the dat...

Page 6: ...s powered via the green G 12 V connector 11 to 16 VDC at 140 mA average current on the front panel of the unit Cable Specifications The Ethernet 10 Base T cable should be a Category 5 twisted pair cab...

Page 7: ...unications ports for communication with your datalogger or other devices in the network To do this you must establish a direct communication link with the NL110 using a PC computer You will need a nul...

Page 8: ...be available at the same time that the PPP is established Ensure the NL110 has an appropriate power source applied Refer to Section 2 1 above Create a new connection in HyperTerminal Choose the COM po...

Page 9: ...g 1 on 0 off the TCP IP address Telnet port address and current communication configuration If Enter is pressed again the NL110 menu prompt will appear After reconfiguring the NL110 for communication...

Page 10: ...keyboard to return to the previous setting All available selections will be listed on the prompt line enclosed in parenthesis with the current setting displayed in brackets at the end of the selection...

Page 11: ...PakBus the NL110 s CS I O port has the following settings CS I O SdcAddr bps This option is used to set up the CS I O port to communicate with the datalogger as an addressable SDC device or a modem en...

Page 12: ...ol PakBus This option is only used when setting up the NL110 to communicate with other PakBus devices in the network Packets transferred over the RS 232 port in this mode are framed as PakBus packets...

Page 13: ...unicate at a maximum baud rate of 9600 bps so to communicate with one of those dataloggers this setting must be 9600 bps or less The default setting is 115K bps RS 232 Serial Server AppId number Enter...

Page 14: ...678 Clock Neighbor Node ID In a PakBus network a neighbor is another PakBus device that the NL110 can communicate with directly e g it does not have to route data through another PakBus device to rea...

Page 15: ...on The string can range from 1 to 20 alphanumeric characters and is case sensitive This security measure is implemented to help prevent unauthorized users from gaining access to the NL110 device Telne...

Page 16: ...10 using the last saved settings that have been programmed by the user This option is different from the Defaults menu item The Defaults menu item resets the NL110 back to the factory defaults After t...

Page 17: ...m to the RS 232 port on the NL110 3 2 Phone Modem Connection to RS 232 A Hayes compatible phone modem is connected to the NL110 to allow a PPP connection for the ESS The phone modem should be connecte...

Page 18: ...NL110 NTCIP Interface 14 This is a blank page...

Page 19: ...a NL110 to put the datalogger into the telecommunications mode 4 RXD Output Serial data transmitted to the datalogger 5 Modem Enable Input Raised by the datalogger when it determines that the NL110 r...

Page 20: ...This is a blank page...

Page 21: ...er handshaking lines An RS 232 null modem cable can be purchased at a local computer store or ordered with your NL110 The pin outs for this cable are provided below Carrier Detect 1 4 Data Terminal Re...

Page 22: ...This is a blank page...

Page 23: ...nected directly to the computer a crossover cable should be used If the NL110 will be connected to the computer through a hub a straight through cable should be used The pin outs for each of these cab...

Page 24: ...This is a blank page...

Page 25: ...168 7 53 10BASE T port network mask 255 255 255 0 Is there a default gatway no PakBus node Id 678 Clock neighbor node Id 1 PakTcp server config enabled PakTcp server port number 4001 PakTcp client con...

Page 26: ...92 168 18 150 Network Mask for PPP 255 255 248 0 PPP Password Max 8 characters ntcip Enable Ethernet Port enabled Set Modem Answer Rings 1 default 1 Modem Initialization AT NL100 105 ver last curr sho...

Page 27: ...gent devices in the manufacturing industry Neighbor PakBus Neighbor Neighbor devices are devices that can be communicated with directly by the current device without being routed through an intermedia...

Page 28: ...This is a blank page...