background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NR-LITE2  

Net Radiometer 

Revision: 6/19 

Copyright © 1998 – 2019 

Campbell Scientific, Inc. 

Summary of Contents for NR-LITE2

Page 1: ...NR LITE2 Net Radiometer Revision 6 19 Copyright 1998 2019 Campbell Scientific Inc ...

Page 2: ...ducts to CSI CSI will return such Products by surface carrier prepaid within the continental United States of America To all other locations CSI will return such Products best way CIP port of entry per Incoterms 2010 This warranty shall not apply to any Products which have been subjected to modification misuse neglect improper service accidents of nature or shipping damage This warranty is in lieu...

Page 3: ...ping address is CAMPBELL SCIENTIFIC INC RMA _____ 815 West 1800 North Logan Utah 84321 1784 For all returns the customer must fill out a Statement of Product Cleanliness and Decontamination form and comply with the requirements specified in it The form is available from our website at www campbellsci com repair A completed form must be either emailed to repair campbellsci com or faxed to 435 227 9...

Page 4: ...e beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit climbing by other persons Take reasonable precautions to secure tripod and tower sites from trespassers Use only manufacturer recommended parts materials and tools Utility and Electrical You can be kil...

Page 5: ...onmental 6 7 Installation 6 7 1 Siting Considerations 6 7 2 Mounting 7 7 3 Wiring 8 7 4 Data Logger Programming 9 7 4 1 Input Range and Integration 10 7 4 2 Calibration Factor 10 8 Operation 10 8 1 Electrical Properties 10 8 2 Spectral Properties 11 8 3 Directional Cosine Response 11 8 4 Sensitivity to Wind Speed 12 9 Maintenance and Troubleshooting 12 9 1 Maintenance 13 9 2 Troubleshooting 13 App...

Page 6: ...he Net Radiation Sensor Mounting Kit 8 7 3 NR LITE2 to data logger connections 9 8 1 Electrical circuit for the NR LITE2 Net Radiometer 11 8 2 Cosine response of a typical net radiometer 12 Tables 7 1 Wire Color Function and Connections to the Data Logger 9 B 1 Wiring for CR3000 Example B 1 B 2 Wiring for CR1000X Example B 2 CRBasic Examples B 1 CR3000 Example Program without Wind Speed Correction...

Page 7: ...ls 2 Precautions READ AND UNDERSTAND the Safety section at the front of this manual Although the NR LITE2 is rugged it is also a highly precise scientific instrument and should be handled as such Care should be taken when opening the shipping package to not damage or cut the cable jacket If damage to the cable is suspected contact Campbell Scientific When installing the NR LITE2 use only the suppo...

Page 8: ...asy way to program your data logger to measure the pyranometer and assign wiring terminals Short Cut is available as a download on www campbellsci com It is included in installations of LoggerNet PC200W PC400 or RTDAQ The following procedure also shows using Short Cut to program the NR LITE2 1 Open Short Cut and click Create New Program 2 Double click the data logger model 3 In the Available Senso...

Page 9: ...k the Wiring tab Click OK after wiring the sensor 5 Repeat steps three and four for other sensors you want to measure Click Next 6 In Output Setup type the scan rate a meaningful Table Name and Data Output Storage Interval Click Next ...

Page 10: ... converted to a single output signal This output represents the net radiation which can be interpreted as meaning the radiative energy that is seen at the surface and is expressed in Watts per square meter W m 2 The NR LITE2 is designed for continuous outside use The sensor surfaces are coated with PTFE This ensures sensor stability long life and easy maintenance compared to the more usual radiome...

Page 11: ...and CR9000 X 6 1 Spectral Spectral range 0 2 to 100 µm Detector type Thermopile Detector protection PTFE coating Detector profile Conical 6 2 Directional Directional error 0 to 60 C at 1000 W m 2 30 W m 2 Sensor asymmetry 5 typical 10 worst case 6 3 Mechanical Housing material Anodized aluminum Cable material Polyurethane Sensor weight 200 g 7 oz Physical dimensions FIGURE 6 1 Sensor 8 0 cm 3 1 in...

Page 12: ...r reflections will be cast on it at any time of day from obstructions such as trees buildings the mast or structure on which it is mounted 1 in FIGURE 7 1 2 To avoid shading or reflection effects and to promote spatial averaging the NR LITE2 should be mounted at least 1 5 m above the ground or crop surface It is recommended that the NR LITE2 be mounted to a separate vertical pipe at least 25 ft fr...

Page 13: ...lock of the mounting bracket kit Make sure the sensor points in the direction of the arrows that appear after the word SENSOR on top of the bracket FIGURE 7 2 4 Perform a coarse leveling of the sensor using the sensor bubble level 5 in FIGURE 7 1 5 Tighten the four screws on top of the mounting bracket to properly secure the support arm so that it does not rotate FIGURE 7 2 Do not attempt to rotat...

Page 14: ...ensor Mounting Kit 7 3 Wiring The NR LITE2 can be measured with a differential or single ended terminal on the data logger a differential terminal is recommended FIGURE 7 3 provides the NR LITE2 wiring Data logger connections are shown in TABLE 7 1 Support Arm Mounting Bracket Pole Support Arm Mounting Bracket Crossarm ...

Page 15: ... supplied wire 7 4 Data Logger Programming Short Cut is the best source for up to date data logger programming code If your data acquisition requirements are simple you can probably create and maintain a data logger program exclusively with Short Cut If your data acquisition needs are more complex the files that Short Cut creates are a great source for programming code to start a new program or ad...

Page 16: ...ed in the data logger program Always cross check to ensure that the serial number of the NR LITE2 and the number on the calibration certificate are identical The serial number and sensitivity are also shown on a small label attached to the connecting arm near the head of the sensor itself When using Short Cut to generate a program you are prompted for the calibration factor Input the factor listed...

Page 17: ...mptions are made The downward facing sensor has the same sensitivity However since the two sensors may not be perfectly symmetrical this assumption may not always be true but differences are small The NR LITE2 sensitivity is the same for both solar and infrared radiation 8 3 Directional Cosine Response The measurement of the radiation falling on a surface also known as irradiance or radiative flux...

Page 18: ...ity is less than 1 of reading per meter per second wind speed and the effect is essentially independent of the radiation level Net radiation readings can be corrected for wind speed sensitivity using the following equation which was developed by Jerry Brotzge at the Oklahoma Climate Survey Wind Sensitivity equation for the NR LITE2 Rn cor Rn obs U 5 m s 1 Rn cor Rn obs 1 0 A U 5 0 U 5 m s 1 Where ...

Page 19: ...ve range on the voltmeter 3 With the lamp switched off read the sensor output signal allow a minute or so for the signal to fully stabilize 4 Switch on the lamp The sensor should now produce a higher positive reading 5 Turn the lamp off again the signal should slowly return to its original level proving the sensor s sensitivity to light 6 Turn the sensor upside down The signal value should reverse...

Page 20: ...d and blue wires The impedance reading should be close to 2 3Ω If it is virtually zero a short circuit is indicated If it is infinite the thermopile is damaged If your readings are not as expected check the following 1 Under full sunlight the expected radiation value is about 1000 W m 2 Under lamps it may be greater For indoor climate studies smaller values are to be expected unless solar radiatio...

Page 21: ...the CRBasic program This program can now be edited for additional refinement Once the file is edited with CRBasic Editor Short Cut can no longer be used to edit the program it created 2 To add the Short Cut wiring information into the new CRBasic program open the DEF file located in the C campbellsci SCWin folder and copy the wiring information which is at the beginning of the DEF file 3 Go into t...

Page 22: ...l Reference 1L Jumpered to Black Shield CRBasic Example B 1 CR3000 Example Program without Wind Speed Correction CR3000 Declare Variables and Units Public BattV Public NR_Wm2 Units BattV Volts Units NR_Wm2 W meter 2 Define Data Tables DataTable Hourly True 1 DataInterval 0 60 Min 10 Average 1 NR_Wm2 FP2 False EndTable DataTable Daily True 1 DataInterval 0 1440 Min 10 Minimum 1 BattV FP2 False Fals...

Page 23: ...lue Signal Reference 2L Jumpered to Black Shield CRBasic Example B 2 CR1000X Example Program with Wind Speed Correction CR1000X Declare Variables and Units Public BattV Public WS_ms Public WindDir Public NR_Wm2 Public CNR_Wm2 Units BattV Volts Units WS_ms meters second Units WindDir Degrees Units NR_Wm2 W m 2 Units CNR_Wm2 Watts meter 2 Define Data Tables DataTable Hourly True 1 DataInterval 0 60 ...

Page 24: ...f WindDir 360 Then WindDir 0 NR LITE2 Net Radiometer dynamic wind speed correction measurement NR_Wm2 and CNR_Wm2 Note that the calibration factor in the Volt_Diff instruction is specific to each sensor VoltDiff NR_Wm2 1 mv200 2 True 0 60 63 29 0 If WS_ms 5 Then CNR_Wm2 NR_Wm2 1 0 021286 WS_ms 5 Else CNR_Wm2 NR_Wm2 EndIf Call Data Tables and Store Data CallTable Hourly CallTable Daily NextScan End...

Page 25: ...0033 0 1 56 45 15 20 Email info campbellsci fr Website www campbellsci fr Germany Location Bremen Germany Phone 49 0 421 460974 0 Email info campbellsci de Website www campbellsci de South Africa Location Stellenbosch South Africa Phone 27 21 8809960 Email sales campbellsci co za Website www campbellsci co za Southeast Asia Location Bangkok Thailand Phone 66 2 719 3399 Email thitipongc campbellsci...

Reviews: