Appendix A. Frequently Asked Questions
PC208W, Version 3.3, Instruction Manual
A-3
Every time there is a telecommunications error, a message pops up even
though I have minimized PC208W. How can I prevent this?
You can’t. PC208W may actually try again and make the connection, but
datalogger communications and data collection are considered important
enough that other applications should be interrupted.
How can I get PC208W to automatically start when the computer is
started?
Add the PC208W Icon to the startup folder on the Windows desktop. Windows
3.1 users need to make sure that Windows is started in the AUTOEXEC.BAT
file, too. You may want to customize the icon’s properties to run minimized.
A.2 EDLOG
I closed a program file and there was another file behind it.
With EDLOG it is possible for the user to open multiple files at the same time.
This allows one program to be viewed while editing another or for program
instructions to be cut and pasted between programs. Selecting FILE | OPEN,
FILE | NEW, or FILE | DOCUMENT DLD FILE does not close any files that
are already open. Select WINDOW | TILE to have EDLOG arrange all open
files so they can be viewed at once.
How do I document a .dld?
Select FILE | DOCUMENT DLD FILE. Then select the .DLD file using the
File Selection window.
Documenting a .DLD file automatically creates a new .CSI file. You do not
need to use the FILE | NEW sequence. The .CSI file is named “ Noname”
until it is saved.
How do I access the Input Location number?
While the cursor is on an Input Location name (i.e., LOC name field is
highlighted), type <Ctrl> and the left arrow cursor key to access the Input
Location number field. Usually this is not necessary as EDLOG will
automatically allocate Input Locations. Pressing <F5> brings up the Input
Location Editor.
How do I add comments to the end of an instruction line?
The END key will move the cursor and place a semicolon at the end of the
line. Comments can then be added.
How do I index or change the sign of a parameter?
To index a parameter, press the <F4> key. Two digit (00) and four digit
(0000) parameters can also be indexed by pressing the “ C” key. Negative
floating point numbers are entered by typing the “ -” key followed by the
number.
Summary of Contents for PC208W
Page 2: ...This is a blank page...
Page 4: ......
Page 58: ...Section 2 Program EDLOG 2 18 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 98: ...Section 3 Report SPLIT 3 40 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 126: ...Section 6 Program Conversion 6 4 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 156: ...This is a blank page...