Appendix A. Frequently Asked Questions
PC208W, Version 3.3, Instruction Manual
A-7
1: Burst Measurement (P23)
1:
00
Input Channels per Scan
2:
00
Range Option
3:
00
In Chan
4:
0000
Trig/Trig/Dest/Meas Options
5:
0.0
Time per Scan (msec)
6:
0.0
Scans (in thousands)
7:
0000
Samples before Trigger
8:
0.0
mV Limit
9:
0000
mV Excitation
10:
0000
Loc [ _________ ]
11:
1.0
Mult
12:
0.0
Offset
EDLOG does not detect when results are stored in Input Locations. It does not
allocate or name Input Locations. This should be done with the Block
command and the Manual flag in the Input Location Editor. If results are set to
be sent to the serial I/O port and no Location is specified for parameter 10, a “
Warning: zero is an invalid inloc address, Line: xx” warning will occur. This
warning can be ignored.
Instruction 80 Set Active Storage Area
The second parameter of Instruction 80 specifies an Array ID or an Input
Location. If parameter one is set to 1 or 2, then an Array ID is expected and
the cursor will move by default to the numeric field. If parameter one is set to
3, then an Input Location is expected and the cursor will move to the label field
by default and the numeric field will display the address of the Input Location.
EDLOG does detect when results are stored back in Input Locations. It does
not allocate or name Input Locations based on the instructions that follow
Instruction 80. This should be done with the Block command and the Manual
flag in the Input Location Editor.
1: Set Active Storage Area (P80)
1:
00
Area Option
2:
0000
Array ID or Loc [ _________ ]
Instruction 81 Rainflow Histogram
This instruction will store results in Input Locations or Final Storage. Thus,
this instruction can be an Output Processing or a Processing instruction.
Parameter 10 is used to specify which mode will be used. If an Input Location
is specified, results will be stored starting at the specified location. In either
mode, output occurs when the Output Flag is set. Set the Input Location
address to 0 to store results directly in Final Storage. This will result in a
“ Warning: zero is an invalid inloc address,
Line: xx” warning which can be ignored.
Summary of Contents for PC208W
Page 2: ...This is a blank page...
Page 4: ......
Page 58: ...Section 2 Program EDLOG 2 18 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 98: ...Section 3 Report SPLIT 3 40 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 126: ...Section 6 Program Conversion 6 4 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 156: ...This is a blank page...