Appendix A. Frequently Asked Questions
A-8
PC208W, Version 3.3 Instruction Manual
1: Rainflow Histogram (P81)
1:
1
Reps
2:
0000
Input Location of Input Data [ _________ ]
3:
0000
Swath (per rep) of Data at Inloc (1=online)
4:
0000
No. of Mean Bins
5:
0000
No. of Amplitude Bins
6:
0.0
Low Limit of Input Data
7:
0.0
High Limit of Input Data
8:
0.0
Min Distance Between Peak & Valley
9:
00
Option (AB)
10:
0000
Loc [ _________ ]
EDLOG does not detect when results are stored in Input Locations. It does not
allocate or name Input Locations other than the location specified in parameter
10. This should be done with the Block command and the Manual flag in the
Input Location Editor.
EDLOG does not calculate Final Storage usage or Specify Final Storage Labels
for this instruction.
Instruction 101 SDM-INT8
The INT8 can be used to make interval or pulse measurements and store the
results in Input Locations or directly in Final Storage. EDLOG does not detect
when results are stored in Input Locations. It does not allocate or name Input
Locations other than the location specified in parameter 7. This should be
done with the Block command and the Manual flag in the Input Location
Editor.
EDLOG does not calculate Final Storage usage or Specify Final Storage Labels
for this instruction.
1: SDM-INT8 (P101)
1:
00
Address
2:
0000
Input Config: Channels 8,7,6,5
3:
0000
Input Config: Channels 4,3,2,1
4:
0000
Function: Channels 8,7,6,5
5:
0000
Function: Channels 4,3,2,1
6:
0000
Output Options
7:
0000
Loc [ _________ ]
8:
1.0
Offset
9:
0.0
Mult
When results are stored in Final Storage, parameter 7 may be left at zero. This
will result in a “ Warning: zero is an invalid inloc address, Line: xx” warning
which can be ignored.
Instruction 15 Serial I/O with a control port
This instruction allows the datalogger to communicate with an RS-232 type
sensor. Characters can be received and/or transmitted.
EDLOG does not name or allocate Input Locations other than the location
specified in parameter 10.
Summary of Contents for PC208W
Page 2: ...This is a blank page...
Page 4: ......
Page 58: ...Section 2 Program EDLOG 2 18 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 98: ...Section 3 Report SPLIT 3 40 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 126: ...Section 6 Program Conversion 6 4 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 156: ...This is a blank page...