Section 3. Report: SPLIT
PC208W, Version 3.3, Instruction Manual
3-9
Example 1
Each time SPLIT runs a parameter file, it keeps track of the number of bytes it
read from the input file and saves this information in the parameter file.
SPLIT can then start where it last left off. This is done by clicking on the
Offsets button and selecting the Last Count option (see Example 1). This
feature may be used to process only the new data from a file in which new data
are being appended periodically to the data file using the scheduled data
collection option of PC208W.
When using the Last Count option, if the Start and Stop
Conditions (Sections 3.3.2, 3.3.3) are specified, they must
exist in the newly appended data or SPLIT will never begin
execution.
By selecting the Specific option and entering a number, SPLIT will "seek" that
position in the file. This option saves time by starting part way through a large
data file. The number specifies the number of characters into the file to seek
before processing data. A positive or negative number can be entered. If the
number is positive, SPLIT will start reading from the beginning of a file; if the
number is negative, SPLIT will start reading from the end of a file. All
characters, including spaces, carriage returns, and line feeds, are counted.
Beginning and ending points may be specified.
Example 2
CAUTION
Summary of Contents for PC208W
Page 2: ...This is a blank page...
Page 4: ......
Page 58: ...Section 2 Program EDLOG 2 18 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 98: ...Section 3 Report SPLIT 3 40 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 126: ...Section 6 Program Conversion 6 4 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 156: ...This is a blank page...