Section 3. Report: SPLIT
PC208W, Version 3.3, Instruction Manual
3-35
Report
A report, with page and column headings, can be sent to a file or printer.
Select the appropriate option in the Report field. A report sent to a file has the
extension of .RPT. If the report is sent to a printer, the printer must be on-line.
The default Output File is also created.
FIGURE 3.3-2. Other Output File Options
Other
The Other button allows the settings below to be modified:
Replace bad data with - The text in the field, to the right of this option,
is entered into the data set if data are blank, bad, or out of range. See
Table 3.3-9 for definition of blank or bad data. Whatever the user enters
in the field will be entered if a blank or question mark is in the data or if
data are out of range. This option is useful when the Output file is
imported into a spreadsheet program, such as Excel.
TABLE 3.3-9. Definition of Blank or Bad Data for each Data File Format
File Format
Definition of Blank or Bad Data
Printable ASCII
????
Comma Separated ASCII
blank or any character except numeral or space
Field Formatted
blank or "" (double quotation marks)
Only display lines with bad data - Outputs only those arrays containing
one or more Out of Range elements. If a report is generated, an asterisk
precedes the Out of Range value in the .RPT file.
Summary of Contents for PC208W
Page 2: ...This is a blank page...
Page 4: ......
Page 58: ...Section 2 Program EDLOG 2 18 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 98: ...Section 3 Report SPLIT 3 40 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 126: ...Section 6 Program Conversion 6 4 PC208W Version 3 3 Instruction Manual This is a blank page...
Page 156: ...This is a blank page...