background image

Warranty and Assistance

The RAVEN II DIGITAL CELLULAR MODEM is warranted by
CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and
workmanship under normal use and service for twelve (12) months from date
of shipment unless specified otherwise.  Batteries have no warranty.
CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to
repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective
products.  The customer shall assume all costs of removing, reinstalling, and
shipping defective products to CAMPBELL SCIENTIFIC, INC.  CAMPBELL
SCIENTIFIC, INC. will return such products by surface carrier prepaid.  This
warranty shall not apply to any CAMPBELL SCIENTIFIC, INC. products
which have been subjected to modification, misuse, neglect, accidents of
nature, or shipping damage.  This warranty is in lieu of all other warranties,
expressed or implied, including warranties of merchantability or fitness for a
particular purpose.  CAMPBELL SCIENTIFIC, INC. is not liable for special,
indirect, incidental, or consequential damages.

Products may not be returned without prior authorization.  To obtain a
Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC,
INC., phone (435) 753-2342.  After an applications engineer determines the
nature of the problem, an RMA number will be issued.  Please write this
number clearly on the outside of the shipping container.  CAMPBELL
SCIENTIFIC's shipping address is:

CAMPBELL SCIENTIFIC, INC.
RMA#_____
815 West 1800 North
Logan, Utah 84321-1784

CAMPBELL SCIENTIFIC, INC. does not accept collect calls.

Non-warranty products returned for repair should be accompanied by a
purchase order to cover the repair.

815 W.  1800 N.
Logan, UT 84321-1784
USA
Phone  (435) 753-2342
FAX  (435) 750-9540
www.campbellsci.com

Campbell Scientific Canada Corp.
11564 -149th Street
Edmonton, Alberta T5M 1W7
CANADA
Phone  (780) 454-2505
FAX  (780) 454-2655

Campbell Scientific Ltd.
Campbell Park
80 Hathern Road
Shepshed, Loughborough
LE12 9GX, U.K.
Phone  +44 (0) 1509 601141
FAX  +44 (0) 1509 601091   

Summary of Contents for Raven II

Page 1: ...RAVEN II DIGITAL CELLULAR MODEM INSTRUCTION MANUAL 5 02 COPYRIGHT c 2001 2002 CAMPBELL SCIENTIFIC INC...

Page 2: ...This is a blank page...

Page 3: ...antability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequential damages Products may not be returned without prior authorization T...

Page 4: ...This is a blank page...

Page 5: ...ssion 30 to 70 C operating temperature range 2 Specifications Transmit Power 600 mW Transmit 824 to 849 MHz Receive 869 to 894 MHz Data Rate 19 2 kbps via TCP IP 1 200 to 38 400 bps via serial interfa...

Page 6: ...n for a Campbell Scientific datalogger is to use a template file The template file is available at Campbell Scientific s FTP resource page http www campbellsci com resource html Alternatively you can...

Page 7: ...tal Cellular Modem 3 In the Open dialog box select the template file that you downloaded After selecting the file the values from the template file will appear in the New Value column in the configura...

Page 8: ...ContentDetails cfm page 61 A power budget can be calculated to determine the length of time the system will run on fully charged batteries without AC or solar charging The number of Amp hours required...

Page 9: ...requirements in half program examples section 6 A user supplied RV or marine deep cycle battery is an economical battery with a larger capacity 60 100 Amp hours Such a battery can be charged with the...

Page 10: ...ade with the following interfaces Datalogger CS I O connection to Raven II Serial Port via SC932 CS I O SC12 Cable SC932 10871 SC12 Serial Port Datalogger CS I O connection to Raven II Serial Port via...

Page 11: ...tructions Instruction 92 sets the port controlling the relay high to turn the power on and a second Instruction 92 sets the port low In these examples control port 1 controls the relay The following p...

Page 12: ...60 I nterval same units as above 3 51 Set Port 1 Low Table 2 Program 02 0 0 Execution Interval seconds Table 3 Subroutines End Program Or one might want to power the transceiver for one hour at 10 a...

Page 13: ...onds into a 2 60 Interval same units as above 3 41 Set Port 1 High 2 If time is P92 1 15 Minutes Seconds into a 2 60 Interval same units as above 3 51 Set Port 1 Low Table 2 Program 02 0 0000 Executio...

Page 14: ...Raven II Digital Cellular Modem 10 This is a blank page...

Page 15: ...AT Command Compatibility 1 S211 Ignore DTR 1 MD Startup Mode Default 0 MD UDP Mode Default 0 S60 Telnet Echo Mode 0 S82 UDP Half Open Mode 0 S83 UDP Half Open Timeout 0 AIP Allow Any UDP IP 0 HOR UDP...

Page 16: ...Appendix A Configuration for use with CSI Dataloggers A 2 This is a blank page...

Reviews: