background image

INSTRUCTION MANUAL

Redwing 100 and Redwing 105

Airlink CDMA Modems

7/04

C o p y r i g h t   ( c )   2 0 0 4

C a m p b e l l   S c i e n t i f i c ,   I n c .

Summary of Contents for Redwing 100

Page 1: ...INSTRUCTION MANUAL Redwing 100 and Redwing 105 Airlink CDMA Modems 7 04 C o p y r i g h t c 2 0 0 4 C a m p b e l l S c i e n t i f i c I n c ...

Page 2: ...ieu of all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequential damages Products may not be returned without prior authorization The following contact information is for US and International customers residing in countries served by Campbell Scientific...

Page 3: ...1 2 Specifications 1 2 1 Base Station Requirements 1 2 2 Datalogger Site Equipment 1 2 3 Power Considerations 2 3 Configuration 2 3 1 Establish Cellular Service 2 3 2 Program the Modem 2 3 3 Setup LoggerNet 3 Appendix A Configuring Modem with a Terminal Emulator A 1 A 1 HyperTerminal Setup A 1 A 2 Programming the Redwing s Phone Number A 2 A 3 Programming the Redwing for Use with a Datalogger A 3 ...

Page 4: ...This is a blank page ...

Page 5: ...igured using the CellSet exe program Datalogger CR510 CR10 X CR23X CR7 CR5000 or CR2XX SC105 or SC932A Interface connects the modem to the CR510 CR10 X or CR7 dataloggers CS I O port 14392 Null Modem Cable connects the modem to the CR23X CR2XX or CR5000 RS 232 port 14394 Redwing Mounting Kit includes mounting hardware for securing the modem to below referenced environmental enclosure and a 9 pin m...

Page 6: ...ed outside the local calling area Contact the provider tell the account representative that you would like to open an account for a new voice phone Request a voice plan similar to Verizon s America s Choice 400 Plan Ask that voice mail NOT be activated The provider will provide you with the following 1 A 10 digit phone number 2 System ID SID You may need to ask for this 3 2 Program the Modem Progr...

Page 7: ...dem on the Tapi Line 5 On the TapiRemote un check Use Tapi Dialing Properties 6 Enter the phone number of the CDMA phone 7 Apply the changes and test If you have a black SC12 cable that is not Rev 1 or newer it is a CS I O cable only and will not work for RS 232 Connect the black SC12 cable between the datalogger and the SC932A Use a 9 pin serial cable or a blue ribbon cable between the phone and ...

Page 8: ...Redwing100 and Redwing105 AirLink CDMA Modems 4 This is a blank page ...

Page 9: ...pbell Scientific Inc Items needed Computer with a COM port 9 pin cable to connect between the computer and the Redwing A terminal program on the computer HyperTerminal 12 volt DC applied to the Redwing CDMA account A 1 HyperTerminal Setup Under Connect using select the COM port you will be using Set COM Properties to Bits per second baud 115200 Data bits 8 Parity None Stop bits 1 Flow control None...

Page 10: ...onfigure Change the baud rate to 9600 Select OK Select Call Call A 2 Programming the Redwing s Phone Number Your provider should give you a Phone number and a System Identification SID number to program into the Redwing Do the following substituting the phone number and SID with yours Example Phone number 4355551212 SID 134 Type AT NAMLCK 000000 then press Enter Type AT NAMVAL 0 4355551212 134 655...

Page 11: ...changed in it to power up ready to work with the datalogger Enter the following Type AT ATINIT C1 D0S0 1 QCVAD 4 IFC 0 0 C then press Enter Type AT ATINITSTATE 1 then press Enter In the above strings all 0 zero Remove the power from the modem and power it up again It should be ready to use Test the communications before deploying the modem NOTE ...

Page 12: ...Appendix A Configuring Modem with a Terminal Emulator A 4 This is a blank page ...

Page 13: ...This is a blank page ...

Page 14: ... campbellsci com br suporte campbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Ltd CSL Campbell Park 80 Hathern Road Shepshed Loughborough LE12 9GX UNITED KINGDOM www campbellsci co uk sales campbellsci co uk Campbell Scientific Ltd France Miniparc du Verger Bat H 1 rue de Te...

Reviews: