Solar Panels 

Campbell Scientific has a range of solar panels of 5W to 100W nominal power output. The SP5, 
SP10 and SP30 have no shunt regulator whereas models SP10R and SP30R are supplied 
complete with a shunt regulator. The general description and specifications given in this 
manual for the SP10 and SP30 also apply to the SP10R and SP30R (see Table 1). The 
differences between the types are clearly stated. Larger panels are supplied with higher power 
regulators to suit the application. 

The SP5 is normally only used with CR200X dataloggers. 

In most climates the SP10 generates enough power to maintain a float charge on a lead-acid 
battery for many applications, allowing the datalogger to be powered continuously. The 
capacity of the battery used depends on the application – battery capacities of 2.5, 5 and 7Ah 
are commonly used. The SP30 can be used where climatic conditions are less favourable or 
where the extra output is needed, e.g. for GPRS communications. Where current drain is 
higher a large battery is often used such as the BP17 or BP24. 

If the datalogger is to be used with ancillary equipment which consumes a significant amount 
of power (e.g. an Eddy Covariance system), the SP60 or SP100 panel is normally specified. 
Under these conditions, the battery capacity should also be increased to suit e.g. using a 
leisure battery of 70-100 Ah. 

1.  Specifications 

 

 

SP5 

SP10 

SP30 

SP60 

SP100 

Typical peak power  
(W)  

4.5(±10%)   

10(±10%)   

30(+/-5%) 

60(+/-5%) 

100(+/-5%) 

Voltage at peak 
power**  

16.5  

16.8  

17.5 

17.5 

18.0 

Current at peak 
power  (A) 

0.27 

0.57  

1.68 

3.43 

5.56 

Short circuit 
current  (A) 

0.30  

0.6 

1.88 

3.84 

6.06 

Open circuit 
voltage** 

20.5 

21.0  

21.0 

21.6 

21.6 

Dimensions 
(excluding bracket)  

269x249 mm  

420x269 mm  

415x510 mm 

535x734 mm 

1037x527 mm 

Weight (excluding  
bracket)  

0.8kg  

1.9kg  

2.95kg 

5.8kg 

7.4kg 

Temp. coeff. of 
voltage (mV/°C) 

 -80  

-72  

-63 

-61 

-61 

Temp. coeff. of 
power (%/°C)  

-0.5 

-0.37  

-0.38 

-0.38 

-0.38 

Cable *** 
termination 

Fixed 4.5m lead 

Fixed 4.5 m 
lead 

0.5 m lead 
with MC3 
connectors 

0.5 m lead with 
MC3  
connectors 

0.5 m lead with 
MC3 
connectors 

*Power ratings are obtained under standard test conditions of 10000 Wm

-2

 and 25°C cell temperature. 

**These are voltages at the panel surface. If an external regulator or long cables are used the apparent output voltage will be lower. 

***Larger panels have two separate output leads fitted with MC3 connectors. A single dual-core extension cable is supplied with mating 
connectors to make the standard total cable length 5m. 

 

Summary of Contents for SP5

Page 1: ...Solar Panels Issued 20 5 15 Copyright 2010 2015 Campbell Scientific Ltd CSL 60 USER GUIDE...

Page 2: ......

Page 3: ...er the repair is under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period it should be accompanied by a purchase order Quotations for rep...

Page 4: ......

Page 5: ...t for recycling Any batteries contained within the product or used during the products life should be removed from the product and also be sent to an appropriate recycling facility Campbell Scientific...

Page 6: ......

Page 7: ...ore beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit...

Page 8: ......

Page 9: ...cid batteries 7 3 4 Using solar panels with the CH150 and CH200 chargers 8 3 5 Using solar panels with Morningstar regulators 8 4 Optimum Battery Size 8 5 Precautions 10 6 Maintenance 10 Figures 1 Gen...

Page 10: ......

Page 11: ...consumes a significant amount of power e g an Eddy Covariance system the SP60 or SP100 panel is normally specified Under these conditions the battery capacity should also be increased to suit e g usi...

Page 12: ...amp provided The panel should face due South North in the southern hemisphere and the angle of the panel should generally be adjusted according to the following considerations For best performance in...

Page 13: ...y details of bracket for the SP5 and SP10 The SP30 and larger standard panels are supplied with a Solar Panel Multi Fit bracket Part number 006607 This is a substantial bracket that fits many differen...

Page 14: ...Solar Panels 4 Figure 3a Assembly drawing for fitting the multi mount bracket to a larger panel Figure 3b Solar panel mounted on pole using the multi mount bracket...

Page 15: ...will vary with the model and make of panel supplied Smaller panels such as the SOP5 are fitted with a flying lead that is moulded into the back of the panel Larger panels have junction boxes on the b...

Page 16: ...e to be wired into cables connecting the panel to the battery The wires of the shunt regulators are clearly identified Connect the shunt regulator as shown in Figure 5 Solar Panel Solar Batt VE VE VE...

Page 17: ...200 and CR6 manuals regarding their LED indicators The CR200X does not have an LED The LED only indicates that a voltage is being generated by the panel it does not necessarily indicate that the batte...

Page 18: ...gulators Please refer to the instruction supplied with those regulators Please note that the quiescent consumption of the regulator may be quite high e g 8 10 mA Please note the fuse warning below 4 O...

Page 19: ...t effective to opt for a much larger battery to cover several months in the winter than to buy a much larger panel to give positive charging at all times If a larger battery is to be used with an exis...

Page 20: ...tly 2 It is important to match panel output to battery capacity and current drain Although an incorrect choice of components can lead to undercharging of the batteries in overcast conditions there is...

Page 21: ......

Page 22: ...entific Centro Caribe S A CSCC 300N Cementerio Edificio Breller Santo Domingo Heredia 40305 COSTA RICA www campbellsci cc info campbellsci cc Campbell Scientific Ltd CSL 80 Hathern Road Shepshed Lough...

Reviews: