Section 6. Troubleshooting
6-7
9.
Type "e" to edit the station file. You should see Figure 6-2 appear on your
screen.
TERM has no idea how to communicate with your station until a station
file is created. This file tells TERM what kind of datalogger is out there,
which serial port to use, the speed of communication, and what kind of
communication device is hooked up to the serial port.
Use the <Enter> key to move around to each parameter. The parameter
that the cursor is presently on will be reverse highlighted. Make sure the
COM port you are using to communicate with the datalogger is the COM
port specified in the station parameter file. To change a parameter in the
station file you will need to move the cursor to that parameter then use the
<Tab> key to change it.
After completing changes, or to exit the station file window, press <Enter>
until you see the save options area. Press <s> to save the file and return to
the main menu window.
TERM: Ver5.0
Com1:9600 baud
Datalogger Type: CR10
Option: None
TERM OPTIONS
C - Call station TORO
T - Terminal emulator
D - Download program to datalogger
S - Save program from datalogger
K - PC time to datalogger clock
P - Create power-up prom file
M - Monitor Input Locations
R - Receive a file
X - Transmit a file
E - Edit station parameters
Q - Quit
Option:_
FIGURE 6-1. Term Main Menu Window
TERM: Ver5.0
NoCom:0 baud
Datalogger Type: None
Option: Edit Station Parameters
Esc = Abort Option
Telecommunication Parameters For Station:
TORO
Datalogger Type:
CR10
Security Code: 0
Use Asynchronous Communications Adapter:
COM1
Communications Baud Rate:
9600
Interface Device:
#1: Short Haul
FIGURE 6-2. Term Station File Window