T107 Weather Station
filter in the cup of water. Remove the filter and allow to air dry before
putting it back on the end of the sensor.
6 months
x
Replace 034B-ET’s anemometer bearings and reed switch if operating
under harsh conditions, such as constant high winds, blowing dust, and/or
salt spray contamination.
1 year
x
Replace 034B-ET wind speed (anemometer) bearings (pn 3648). Contact
your local Toro distributor for service.
x
Replace 034B-ET wind speed (anemometer) reed switch (pn 13764) if
needed. Contact your local Toro distributor for service.
x
Check calibration of the HMP60-ETS temp/RH probe. Sensor will tend to
drift up over time giving readings higher than 100%. Replace RH chip (pn
9598) if necessary (see FIGURE 4-1 and Section 4.1.4.1,
Procedure for
Removing RH Chip
).
T107 stations began shipping January 2014 with an updated gill
radiation shield retained with knurled thumb screws, using the
HMP60-ETS Temp/RH sensor. All information in this document
is also pertinent for the HMP50-ET, HMP60-ET, and HMP60-
ETR sensors.
x
Replace desiccant in enclosure housing as needed.
FIGURE 4-1. Exploded view of the temperature and RH sensor
(adapter not shown)
NOTE
Protective Cap
and Filter
Shipping Cap
(remove prior
to installation)
9598 RH Chip
57
Summary of Contents for T107
Page 2: ......
Page 3: ......
Page 49: ...T107 Weather Station FIGURE 2 31 Slide Antenna Bracket U Bolt around Back of the Pole 41...
Page 78: ...T107 Weather Station 70...
Page 93: ...Appendix C Exploded Views C 1 Enclosure C 1...
Page 94: ...Appendix C Exploded Views C 2 Crossarm C 2...
Page 102: ...Appendix D Default Programs D 8...
Page 105: ......