seated on the connector and the locking ring is turned a quarter revolution clockwise.
10. Install the wind vane using the Allen wrench supplied with the vane. Wind vane should be
perpendicular to the crossarm.
11. Put the MetOne sticker over the wind vane Allen screw opening.
12. Remove and keep the shoulder screw. The shoulder screw will be needed for replacing
bearings and/or potentiometer. The wind vane and cups should turn freely.
13. Plug the cable into the WS/WD connector on the enclosure. Ensure that the plug is
completely seated on the connector and the locking ring is turned a quarter revolution
clockwise.
WARNING:
Plugging this sensor into the SDI-12 connector can damage this sensor, the main enclosure
connector board, or both.
6.6.3 WindSonic 2-D Ultrasonic Wind Sensor (wind sensor
option -GW)
When the WindSonic1-ET is added to the T107, a jumper setting must be changed (
NOTE:
Jumper is set at the factory if the WindSonic is ordered with the T107 station.
6.6.3.1 Changing the jumper
The procedure to change the jumper follows:
1. Remove the cover of the enclosure.
2. Disconnect the ribbon cable from the CS I/O port.
3. Use a Philips screwdriver to loosen the four screws (
Section 6. Installation
26