2. Replace the connector cover. The tab at the top of the connector cover slides into the
opening on the back of the crossarm. Ensure that all cables and connector caps are under
the cover before tightening the Phillips screw at the bottom of the cover. Make sure that all
cables coming out of the top right of the connector cover are not being pinched.
FIGURE 6-45. Connector cover in place
3. Tighten the wire ties holding the cables to the wire tie harness and clip off excess ties
(
(p. 57)).
6.12 Sealing and desiccating the enclosure
The T107 enclosure is supplied with two desiccant packs. The desiccant maintains a low humidity
in the enclosure to minimize the chance of condensation on the instrumentation. Desiccant
should be changed when the internal enclosure humidity sensor measures 50% or higher. Install
the desiccant as shown in
(p. 58). Keep unused desiccant tightly sealed in an
airtight container.