background image

12

13

Setting the video operating channel remotely

In order to set the video transmission operating channel (for a specific 

transmitter) remotely from the CAM-9 M Rx receiver level,  
do the following:
1 .  Select the 

 option from the main menu .

2 . 

Select the identification number of the transmitter whose video 

transmission operating channel you intend to change with the ENTER 
button 

[I] 

and then confirm the selection by holding the SET button 

[H]

 .

3 .  The receiver will communicate with the transmitter and the video 

transmission operating channel currently set in the transmitter will 
appear on the display .

4 .  Select the desired operating channel with the ENTER button 

[I] 

and then 

confirm it with the SET button 

[H]

 .  

5 .  If the selected operating channel appears on the display 

[B] 

blinking, 

then it has been configured properly. If the 

, symbol appears instead, 

it indicates a transmission error (repeat steps from 1 to 4)

6 .  The device will return to the main menu .

Setting the data transmission parameters remotely

In order to set the data transmission parameters (data rate and format) 
remotely from the CAM-9 M Rx receiver level, follow the instructions 
in the 

[Method for setting the transmission rate and data format]

 

section at page 10 . When the radio link parameters are being set, the 
receiver, if its memory contains transmitters assigned to it, automatically 

communicates with the transmitters and the entire network is configured 

according to the CAM-9 M/S Rx receiver parameters .

Advanced settings

Testing the data link

In order to test the correctness of data transmission between the CAM-
9 M Rx receiver and the CAM-9 transmitters, select the    option from 
the main menu . The procedure will commence automatically . Testing can 
be conducted both from the receiver and transmitters levels .
When the testing is completed, the result will appear on the display . The 
display method depends on whether the testing was conducted from the 
transmitter or receiver level . 

Testing from the CAM-9 Tx transmitter level

 

- If, after testing is completed, the display alternates between

 

 (OK) 

and the transmitter’s ID number, it indicates a correct transmission . 

 

- If  , appears on the display, it indicates a transmission error (check 

the connections and test again) .

Testing from the CAM-9 M Rx receiver level

 

 

- If, after testing is completed, the display alternates between 

 (OK) 

and the number of transmitters entered into memory, it indicates 
a correct transmission .

 

- If the display alternates between    and a number, it indicates 

a transmission error between the receiver and the transmitter with 
this ID number .

Removing a transmitter from the CAM-9 Rx receiver memory

 

-

If there is a need to turn one of the transmitters off permanently 

(removal, damage), it should be deleted from the CAM-9 M Rx 
receiver memory . In order to do this, select the    option from the 
main menu in the receiver .

 

- Next, select the ID number of the transmitter to be deleted with the 

ENTER button 

[I] 

and confirm the selection by holding the SET button  

[H]

 . The transmitter will be deleted from the device memory and will 

no longer be visible during testing, setting parameters, etc .

Restoring the device to default settings

 

- In order to reset the transmitter or receiver to the default settings, 

disconnect the device’s power supply, press the ENTER button and 
connect the power supply again .

 

- The display will count from 5 to 1, the ENTER button should be 

held during that entire time . The device will reset itself to the 
default settings .

Summary of Contents for CAM-9

Page 1: ...IP65 8 CHANNELS BNC VIDEO BNC VIDEO UTP VIDEO 5 8 GHz 25 mW FM PAL NTSC VIDEO 10 CHANNELS 869 MHz 300 mW GFSK RS 485 DATA Operating manual Warranty Terms CAM 9 Wireless system for simultaneous transmission of video audio and control for PTZ cameras ...

Page 2: ...tting the data transmission operating channel 9 Advanced settings 11 Procedure for assigning transmitters to the receiver memory 11 Setting the video operating channel remotely 12 Setting the data transmission parameters remotely 12 Advanced settings 12 Testing the data link 12 Removing a transmitter from the CAM 9 Rx receiver memory 13 Restoring the device to default settings 13 General warranty ...

Page 3: ...after the previous kit has been set up precisely 2 It is recommended to install CAM 9 receivers at least 7 m away from digital receivers CDS 5021 CDS 5IP and other 3 It is not permitted to power devices without antenna cables screwed into the SMA connectors In order to ensure a stable radio range the antennas have to see each other optically One hundred percent optical visibility should be provide...

Page 4: ... Device external dimensions Tx 152 103 60 mm Rx 164 164 80 mm The number of usable channels depends on the regulations in the specific country The use of 8 channels is permitted in the European Union countries while in many countries outside of the Union 16 channels can be used We recommend using high quality power supplies high efficiency transformer based or impulse ones with low current ripplin...

Page 5: ...d 5 705 5 945 GHz 16 operating channels can be used only in selected countries outside of the European Union In order to change the frequency band for video transmission use switch no 2 OFF position 8 operating channels ON position 16 operating channels permitted only in selected countries outside of the EU Video transmission settings Setting the video transmission operating channel 1 In order to ...

Page 6: ...o the CAM 9 M Rx receiver memory Procedure for assigning transmitters to the receiver memory 1 Select the option from the main menu in the receiver Menu options are selected by pressing the SET button H shortly 2 The display in the receiver will show the number of transmitters currently entered into memory This value will blink indicating that the assigning procedure is active 3 Select the option ...

Page 7: ...elect the option from the main menu The procedure will commence automatically Testing can be conducted both from the receiver and transmitters levels When the testing is completed the result will appear on the display The display method depends on whether the testing was conducted from the transmitter or receiver level Testing from the CAM 9 Tx transmitter level If after testing is completed the d...

Page 8: ...ubject to penalties provided for in the appropriate regulations General warranty terms Camsat grants a 24 month warranty for the Cam 9 transmission kit 1 If the device is not be operating properly make sure before returning the device for servicing that everything was done according to the operating manual 2 If the faulty device is returned or send in for repairs a thorough written description of ...

Page 9: ...Manufacturer CAMSAT Gralak Przemysław Ul Ogrodowa 2a 86 050 Solec Kujawski Product offer and information www camsat com Service service camsat com ...

Reviews: