If the WPA data encryption method is selected, a network key is required, the same for
all the CDS-5IP mini units. The user can select the encryption key type in the Data
Encryption menu:
64-bit WEP: consists of no more than 10 hexadecimal characters.
128-bit WEP: consists of no more than 26 hexadecimal characters.
9. The list of available frequencies (for the default channel width of 40 MHz)
Use the respective channels according to their intended purpose:
Selecting other frequencies depends on legal regulations applicable in the coun-
try of use. If not sure what regulations are applicable in the country of use, con-
sult with the CDS-5IP mini module seller.
indoor – only inside buildings,
outdoor – only outside buildings.
Adjustment
Range (intended use)
ETSI (European Union)
5,15 ~ 5,25 GHz
indoor
5,25 ~ 5,35 GHz
indoor
5,50 ~ 5,70 GHz
outdoor
36
44
52
60
100
108
116
124
136
5180
5220
5260
5300
5500
5540
5580
5620
5680
Channel frequency
Channel number
16
EU
EU
POLISH
MARK
POLISH
MARK
CDS-6IPECO User’s manual