Baseplate Cooling & Temperature Management 

The temperature management of the CPS-EC series provides a direct dissipation of the main energy losses. 
The internal coolers of the output diodes and the power FETs connect to the back-plate cooler. It is possible to 
dissipate about 40 – 50% of the energy losses out of a system while using the Baseplate cooling bundle 
2201002001 to hard mount the unit to a plane and heat conductive surface.  

 

Parallel Operation & Decoupling 

To increase the output power up to 5pcs of the CPS-EC units can be parallel 
connected. Advise using busbars to connect several devices in parallel. Always 
use identical cabling length and identical cross sections to the busbar or a star 
point. When sensing is required, we recommend connecting the sense lines to 
a star point located very close to the load. To avoid erroneous measuring the 
cable section from the star point to the load shall be as large and as short as 
possible. 
 
The CPS-EC models have no internal O-ring diode. For decoupling devices 
N+1. Up to 125Vdc we recommend using our RED00202 DIN rail diode module. 
It is capable to decouple 2pcs of the CPS-EC power supplies from each other. 
To increase the power capability RED models can be connected in parallel. For 
higher voltages, an external decoupling diode shall be installed from the system 
engineer. 

 

Coating Option 

We offer the CPS-EC series with an optional coating. It is to be used in e.g., dusty, dirty, high humidity area or 
in awaiting quick temperature changes. Short circuit and corrosion at print board lines and at solder points can 
be prevented. The coat itself is a transparent acrylic resin.  
Peters SL 1306 N-FLZ (transparent) IEC60216-1 2001, IPC-CC-830B, UL listed as permanent coating  
File No.: E80315 , UL94V-0 
Ordering Information: add extension 

C

 to the model name (example): CPS-EC480.048

C

(R2)

 

 

Electrical Safety (Factory-Test / Field-Test Owner)

 

 
 
 
 
 
 
 
  
¹) 

48Vdc= 2500Vdc 

 

Type and factory test are the manufacturer. While repeating damage can  
happen to the power supply unit. For the field test (owner) follow the below instruction:

 

a) 

Use suitable test equipment, raising the voltage slowly 

b) 

Short circuit L1 and N, and all the DC output terminals. 

c) 

Use only test voltages of 50/60Hz. The outputs are unearthed and 
therefore they have no resistance to GND/PE. 

d) 

If the residual voltage is 

60Vdc, observe the safety standards. 

Use only specially insulated screwdriver to trim the Ua/Ia. 
 

 

Connections 

AC Main Input               

GND common                                    
N - wire                                  
L - wire                                                                                 

DC Mains 

 

DC + voltage                             
DC + voltage    
DC - voltage            
DC - voltage 

Inputs/Outputs 

Imon   = current monitor output

 

SD  

= shut down input 

INH       = Inhibit Connection 
DC-ok  = power good relay 

Sense 

B= sense connections (S+/-) 
 
 

 

 

C

1

)

 

Type Test 

60s 

2500Vac 

3000Vac 

500Vdc 

3000Vac 

500Vdc 

Factory Test 

5s 

2000Vac 

2000Vac 

500Vdc 

900Vdc 

500Vdc 

Field Test 

2s 

2000Vac 

2000Vac 

500Vdc 

900Vdc 

500Vdc 

Cut-off current setting  >20mA 

>20mA 

>1mA 

>1mA 

>1mA 

 

Summary of Contents for 2201002001CA

Page 1: ...ontrol 1V per load line Electronic inrush current limiter 13 8Apeak Inhibit function Interlock External shutdown Efficiency up to 92 Precise dynamic response to load change Designed for long life under full stress Strong input filters Hold up time 50ms Soft start auto recovery High reliability shock vibration proof EMC meets CE norm class B Overload and short circuit protection Large terminals 4x ...

Page 2: ...ed with a 15 turn high precision potentiometer The listed values are guaranteed by the factory The tolerance of the upper margin is 0 5 The tolerance of the lower margin is 5 0 Output Current Monitoring The CPS EC power supply features a 0 5Vdc signal output It is a real time linear signal and indicates the current consumption of the load The measuring point is directly at the output connection of...

Page 3: ...ed isolation to the inputs and the output 3000Vac Sense Function Compensation 1V per load line Remote Shutdown Yes protective forced isolation to the inputs and the output 3000Vac Inhibit Function Interlock Yes protective forced isolation to the inputs and the output 3000Vac Derating 60 C 70 C 2 5 C Accuracy 1 5 interface Load Regulation 0 05 0 100 Start up from Shutdown Typ 320ms Start up from In...

Page 4: ... output Sense Compensation 1V per load line AWG22 AWG6 0 25 2 5mm Sense Aux 3000Vac to input Power Good Relay b contact AWG22 AWG6 0 25 2 5mm DC OK 3000Vac to input output All potentiometers and all the inputs and the outputs of the analogue interface provide a forced isolation It is to ensure a protective isolation for the 300Vdc DC Voltage Current adjustment range Rated DC Voltage 24Vdc 36Vdc 48...

Page 5: ...ARNING Reverse polarity of the sense lines can cause damages to the power supply unit To basically prevent from interferences enable to twist sense compensation lines To reduce inductive influences make sure that the load wires are installed close to each other Driving a pulsative load requires a large electrolytic and a ceramic capacitor Make sure that C1 C2 are not oscillating with load wires It...

Page 6: ...y setting for DC input supply The below table of values shows the hysteresis of the lower and upper threshold margins where the DC OK Relay indicates a low voltage The nominal voltage of the cell voltage of a typical lead acid battery VRLA vented GEL AGM is listed OPsZ OPzS OPzV OGi OGiV GiV types WARNING Regarding the DC output voltage setting range it is important to consider that this data shee...

Page 7: ...PS EC480 048 58 8 3 48 10 0 480W CPS EC480 060 75 6 4 60 8 0 480W CPS EC480 072 90 5 3 72 6 7 480W CPS EC480 110 137 5 3 5 110 4 4 480W CPS EC480 150 180 2 7 150 3 2 480W CPS EC480 220 264 1 8 220 2 2 480W CPS EC480 300 360 1 3 300 1 6 480W Inrush Current Limiter The unit is featured with an electronic inrush current limiter ex 230Vac 9 8Arms 13 8Apeak The built in circuit is a very precise limite...

Page 8: ...ies from each other To increase the power capability RED models can be connected in parallel For higher voltages an external decoupling diode shall be installed from the system engineer Coating Option We offer the CPS EC series with an optional coating It is to be used in e g dusty dirty high humidity area or in awaiting quick temperature changes Short circuit and corrosion at print board lines an...

Page 9: ...t in injury or death Mechanics Mechanics Stable metal aluminum housing IP20 To allow adequate convection a free air space of 50mm top bottom and 5mm sidewalls is required for active devices 15mm space from the sidewalls For free air convection it is necessary to install the unit horizontal Use the DIN Rail installation equipped standard with the patented 35mm DIN Rail brackets according to EN60275...

Page 10: ...and for active devices 15mm space from the sidewalls For proper air convection it is necessary to install the CPS EC480 One can use the DIN Rail installation equipped standard with our patented 35mm DIN Rail bracket according to EN60275 It is easy to mount dismount while snaping it onto the 35mm DIN Rail no tools necessary A wall mount back plate option is available too It is not allowed to instal...

Page 11: ... DIN 46228 pt 1 min max 2 5 10mm 0 2 1 5mm Plug gauge in accordance with EN 60999 a x b ø 5 4 x 5 1mm 5 3mm 2 4 x 1 5mm 2 3mm Pitch P 10 16mm 3 5mm Wire Stripping Length fine wired Nominal Cross Section Wire End Ferrule Stripping Length Wire End Ferrule Stripping Length 0 25mm H0 25 5 5mm H0 25 10 HBL 8mm 0 5mm H0 5 6 6mm H0 5 12 OR 8mm 1 0mm H1 0 6 6mm H1 0 12 GE 8mm 2 5mm H2 5 12 12mm H2 5 19D B...

Page 12: ...ing bolts or operation outside the specified herein specification or in an unsuitable environment has the immediate loss of warranty to follow We disclaim any responsibility for any resulting damage to persons or things 4 Note The device must not be operated without an upstream circuit breaker CB We recommend the use of B Type 16A for 230Vac and for 115Vac It is prohibited to use the unit without ...