CPS-i2000(R2) MANUAL
Mechanics
Aluminium-housing IP20.
Cooling is achieved via
front-to-rear fans.
To ensure adequate heat
dissipation, 50mm to the
front and 150mm
blockade-free distance
from the device back wall
must be guaranteed.
The harnesses are to be
designed and installed to
that the air outlet of the
unit is not being blocked.
In a rack mounting of
multiple subracks, the rear
distance of the cable-
management increases,
depending on the type of
the air duct.
An optional cable-
accession assistance for
the racks will be available
soon.
sales@powersolve.co.uk
www.powersolve.co.uk
020321