CPS-i2000(R2) MANUAL
Technical Data Table
AC Input Range
184-264Vac
AC Input Frequency
47-63Hz
DC Input Range
250-375Vdc
AC Input Rated
230Vac <10A
DC Input Rated
250Vdc <9,3A 375Vdc <6.2A
DC Voltage Programmable
0 - 18Vdc
0 - 30Vdc
0 - 60Vdc
0 - 90Vdc
0 - 150Vdc
DC Current Programmable
0 - 165A
0 - 100A
0 - 50A
0 - 33A
0 - 20A
Over Voltage Protection
21Vdc
35Vdc
70Vdc
105Vdc
175Vdc
Over Current Protection
182A
110A
55A
36,3A
22A
Ripple Noise 230Vac 20MHz 35mVpp
35mVpp
75mVpp
100mVpp
200mVpp
Auxiliary Voltage
12Vdc/0,5A accuracy ±0,5V R&N 30mVpp, not influenced from SB, SD, INH operations
Power Rated
2000W, 184-264Vac
Cooling
Continuously controlled and monitored fans from EBM Papst (Germany)
Efficiency
typ. 92-94% 230Vac at full load
Power Factor Control (PFC)
0,99 / 230Vac under full load
Short Circuit Resistance
yes
Open Circuit Protected
yes
Base Load (OCP)
Non required (open circuit protected)
Load Regulation
< ± 0,05% 0-100%
Load Regulation Time
<1ms on load switch 10-100%
Accuracy
Ureg:
≤
± 0,5%, Ireg:
≤
± 1%, Umon:
≤
± 0,5%, Imon:
≤
± 1%, Uref:
≤
±1%
Temperature Control
yes, thermal shutdown & autorecovery (+70°C, outside measuring point distance 10mm)
Hold Up Time
>30ms 230Vac
mains buffering at full load
Inrush Current
<14,6Aeff <20,7Apeak 230Vac active electronic inrush protection (no simple NTC)
Startup Delay
typ. 1s
Softstart
typ. 100ms
Ambient Temperature
- 20°C…+60°C operating, derating 2,5%/°C >50°C
Storage Temperature
- 40°C…+85°C
Ambient Conditions
Humidity 95% non-condensing @ 25°C, climate class 3K3, pollution degree 2
ROHS
2011/65/EU, (EU) 2015/863 conform
REACH
EG No. 1907/2006 conform
EMI for the models
EN55032, conducted .018/.030/.060 class B / .090/.150 class A, all models radiated class A
EMS/EMI
EN61000-6-2,3,4
Safety
EN61010-1, EN61010-2-201, EN62368-1, EN60950-1, EN60204-1
Protection Class I
PE connection required
Leakage Current
Typical 1.9mA, <2.8mA, 230Vac 50Hz
Isolation Input to Output
3000Vac
Isolation Input to Case
2500Vac
Isolation Output to Case
500Vdc ,
≥
60Vdc= 2800Vdc
MTBF (IEC61709)
419000h (Meantime Between Failures: statistic time between failures after repairs)
MTTF (IEC61709)
146105h (Meantime To Failure: statistic time to ever fails)
Dimensions (HxWxD)
84x126,4x444mm | 3,3x5x17,5 Inch (without frontplate, note cable outlet in planning)
Weight
4,4kg / 9,7lbs
Input Power Connections
Neutrik NAC3FCA (locked by bajonett) included
Output Power Connections
Brass-Powerbars with metric M8 thread, a touch protection is included
Programming Time Vout [ms]
Model
0-18Vdc
0-30Vdc
0-60Vdc
0-90Vdc
0-150Vdc
Rise Time 0-100%, 10/100% Load, [ms] typ.
15/15
15/15
15/15
15/15
15/15
Slew Rate 90-10%, 10/100% Load, [ms] typ.
25/2,5
70/7,0
49/4,9
35/3,5
47/4,7
Slew Rate PS-Option 100-0%, 0% Load, [ms] typ. 200
200
200
200
200
Output Capacity, [mF] typ.
19,4
19,4
3,4
1,07
0,52
Latency [ms]
1
1
1
1
1
sales@powersolve.co.uk
www.powersolve.co.uk
020321