background image

 

 

   

HSEUREG07201(R2) MANUAL

                 

Camtec Power Supplies GmbH  -  Gewerbestrasse 30  -  DE-76327  Pfinztal / Germany

       

P.2/10 (12/2017.02.1)

 

Phone +49 (721) 46596-0  -  Fax +49 (721) 46596-77 – 

www.camtec-gmbh.com

 - 

info@camtec-gmbh.com

 

(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death) 

 

Technical Concept 

 
The Camtec HSEUREG models are high-precision lab power supplies „Made in Germany“. These power supplies are designed 
for power systems in the testing automation and for industrial use.

  

 
For more than 25 years the Camtec Power Supplies manufactures high-end switch mode power supplies in Germany. A field breakdown of 
below 0,004% over a 10-year period under review approves our ambitious quality concept. Each manufactured Camtec product passes 
100% tests for each detailed function and a full-load Burn-In test.  
 
Although it is not required from the safety norms our production applies a routine safety test to each manufactured device, even if it is an 
extra low-voltage model. The components in the assembled device pass stress aging to achieve an even level and to prevent from delayed 
failures. Our internal product engineering guidelines provide a clear target: Camtec product reputation must say „mount and forget“. Quality 
is never a mere promise for our team. 
 
The HSEUREG laboratory power supplies provide low noise and ripple, a very quick programming, and a precise setting at high load 
changes. With an efficiency up to 90% the devices are highly energy efficient. 
 
Equipped with high-end capacitors of outstanding lifetime our power supplies guarantee a very long and reliable operation time. The circuit 
design of the HSEUREG Series allows cope playing with complex loads. The internal protection circuits protect the power supply and the 
connected system, even in exceptional situations. The HSEUREG series is protected from high transients by strong filters with high energy 
efficiency. All inputs and outputs are electrically isolated. The design specifications call for the highest standards of safety and interference 
suppression. 
 
The 480W and 720W models provide natural convection. The 1kW models use a forced air-cooling system with a fan. In selecting the fan, 
as with all our power supplies, in our opinion we use with the German manufacturer EBM Papst the highest quality and most reliable 
devices in the world market. 
 

Design Conception 

The HSEUREG power supply series realizes high programmable power in a space-saving housing. Latest generation electrical devices 
relate to the high reliability of all CAMTEC products. The CAMTEC philosophy is, to employ 125°C low ESR ultra long-life capacitors where 
expedient to achieve a superior lifetime of the product. The HSEUREG power supply is made for high reliable and demanding industrial 
applications like galvanic systems, professional DC-drives, and complex test benches 
 

Programming Performance

 

THE HSEUREG power supply is very equal to a typical laboratory power supply – just without its displays. It is designed for automated 
industrial test benches in a 24/7 operation. The HSEUREG provides save and precise down to zero voltage programming. The product is 
equipped with a multi-functional interface. Thus, the interface can be operated with either 0-10Vdc/20mA or with 0-20mA programming. 
The burden is 500

Ω

 to ensure interference free operation with controller interfaces. The device features a small latency and a quick all rise 

time that leads to typical 15ms from zero to Umax programming. 
 

Galvanic Isolation  

The power supply is galvanic isolated between the input and the output. All features are connected to the DC power outputs.

  

 
Thermal shutdown 

The HSEUREG is featured with a thermal overload shut down and auto recovery behaviour. 
 

Over Voltage Protection 

Ticker mode and auto recovery 
 

Short Circuit Protection

 

A continuous short circuit does not cause damage to the power supply. The HSEUREG delivers constant current and zero output voltage. 
It recovers automatically after the short circuit is released. 
 

Open Circuit Protection 

The HSEUREG series is continuously open circuit protected. The device delivers a stable output voltage and no current. If a load is 
immediately connected to the device, the power supply stabilizes within 1ms. It does not overshoot the output voltage. 
 

Power Up Ramp

 

The devices have a soft start ramp when powering up. The device does not either overshoot the voltage nor does the output flutter 
independent if a load is connected or not. 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for HSEUREG07201.015

Page 1: ...IN Rail Specification Voltage programming from 0V Multi interface 0 10V 0 20mA Sense Shutdown remote ON OFF N 1 parallel operation Natural convection Precise dynamic response on load change Designed for long life under full stress Strong input filters High reliability shock vibration proof Over Voltage and continuous short circuit protection EMI EMS EN61000 6 2 3 EN55032 class B EN61010 1 EN61010 ...

Page 2: ...atural convection The 1kW models use a forced air cooling system with a fan In selecting the fan as with all our power supplies in our opinion we use with the German manufacturer EBM Papst the highest quality and most reliable devices in the world market Design Conception The HSEUREG power supply series realizes high programmable power in a space saving housing Latest generation electrical devices...

Page 3: ...n protective electrical separation 60Vdc Analogue Interface see table protective electrical separation 60Vdc working impedance 500Ω Accuracy 1 5 Interface Latency Interface 15ms including signal latency for 0 Umax programming Start up Delay Typ 250ms Softstart Typ 100ms Start up from Shutdown Typ 250ms Response Load Change 1ms 10 100 100 10 Base Load None Efficiency 230Vac 90 typical Short Circuit...

Page 4: ...unctional interface 500 Ω working resistance with voltage programming 2 Ureg Input 3 Sense Input Sense Control none Compensation max 2V per load line 4 Sense Input 5 Remote Input External Shutdown Remote ON OFF Open Collector or Switch Voltage drop 1V with typical 2 3mA 6 Remote Input Programming Interface Ureg The standard programming of the HSEUREG Series is an analogue interface The output volt...

Page 5: ...o allow proper operation Remote Sensing Schematics Although the HSEUREG sense block is simpler it applies to the shown schematics Please note that the HSEUREG has no AUX connection feature and that the sense block has only connections We recommend twisted sense lines Local Sensing Remote Sensing Compensation of Load Line Drop Voltage Sense battery charger operation mode Remote Sensing as a battery...

Page 6: ... sections of all power supplies to the busbar or to the star point are identical Allow proper connection for low contact resistance If you want to use the sensing function connect it also to the star point or busbar To avoid measurement errors select the line length from the neutral point or from the busbar to the load as short as possible and use the maximum possible conductor cross section The H...

Page 7: ...rein a failure or malfunction could result in injury or death Mechanics ST HD Baseplate Cooling Temperature Management The temperature management of the HSEUREG series provides a direct dissipation of the main energy losses The internal coolers of the output diodes and the power FETs connect to the back plate cooler It is possible to dissipate about 40 50 of the energy losses out of a system while...

Page 8: ...a free air space of 50mm top bottom and 10mm sidewalls is required and for active devices 15mm space from the sidewalls One can use the DIN Rail installation equipped standard with our patented 35mm DIN Rail bracket according to EN60715 It is easy to mount dismount while snaping it onto the 35mm DIN Rail no tools necessary It is not allowed to install the HSEUREG in other mounting direction then b...

Page 9: ... accordance with EN 60999 a x b ø 5 4 x 5 1mm 5 3mm 2 8 x 2 4mm 2 5mm Pitch P 10 16mm 5 08mm Wire Stripping Length fine wired Nominal Cross Section Wire End Ferrule Stripping Length Wire End Ferrule Stripping Length 0 25mm H0 25 5 5mm H0 25 10 HBL 8mm 0 5mm H0 5 6 6mm H0 5 12 OR 8mm 1 0mm H1 0 6 6mm H1 0 12 GE 8mm 2 5mm H2 5 12 12mm H2 5 19D BL 14mm 4 0mm H4 0 12 12mm H4 0 20 GDR 14mm 6 0mm H6 0 2...

Page 10: ...bolts or operation outside the specified herein specification or in an unsuitable environment has the immediate loss of warranty to follow We disclaim any responsibility for any resulting damage to persons or things 4 Note The device must not be operated without an upstream circuit breaker CB We recommend the use of C Type 16A for 230Vac or 25A for 115Vac It is prohibited to use the unit without P...

Reviews: