Temperature Derating

 

The maximum ambient temperature during operation is + 60°C. If the over 
temperature protection is activated, the power supply is switched off. 
 
 
The measuring point is 50mm outside the power supply. The power supply 
unit starts automatically when it has cooled down. 
 
 

 

Series Operation

 

Two or more units of the same model and output voltage can be operated up to a total voltage of 240Vdc in 
series. Due to the dielectric strength of the internal components used, only the models with an output voltage of 
90Vdc and later are approved for series operation. Other power supplies are not approved for series operation 
above 60Vdc. 
If the units are remotely controlled via the analogue interface it is compulsory to use a potential-free control 
voltage! 

 

Parallel Operation & N+1 Decoupling

 

To increase the overall power of the power supply, two or more devices of 
the same model with the same output voltage may be operated in parallel. 
We recommend using a busbar for the DC power connector. Make sure 
that the cable lengths and cable cross-sections of all power supplies to 
the busbar or to the star point are identical. Allow proper connection for 
low contact resistance. If you want to use the sensing function, connect it 
also to the star point or busbar. To avoid measurement errors, select the 
line length from the neutral point or from the busbar to the load as short as 
possible and use the maximum possible conductor cross-section. 
 
The HSEUREG models have no internal O-ring diode, to operate the 
devices N+1 redundant. 

 

Coating Option

 

We offer the HSEUREG-series with optional coating. It is to be used in e.g. dusty, dirty, high humidity, or in 
awaiting quick temperature changes. Short circuit and corrosion at print board lines and at solder points can be 
prevented. The coat itself is a transparent acrylic resin. Peters SL 1306 N-FLZ (transparent) IEC60216-1 2001, 
IPC-CC-830B, UL listed as permanent coating FileNo.: E80315 , UL94V-0 

 

Electrical Safety (Factory-Test / Field-Test Owner) 

 
 
 
 
 
 
  
¹) 

90Vdc= 2000Vdc 

 

Type and factory test are the manufacturer. While repeating damage can  
happen to the power supply unit. For the field test (owner) follow the below instruction:

 

a) 

Use suitable test equipment, raising the voltage slowly 

b) 

Short circuit L1 and N, and all the DC output terminals. 

c) 

Use only test voltages of 50/60Hz. The outputs are unearthed and 
therefore they have no resistance to GND/PE. 

d) 

If the residual voltage is 

60Vdc, observe the safety standards. 

Use only specially insulated screwdriver to trim the Ua/Ia. 
 

 

 

C

1

)

 

Type Test 

60s 

2500Vac 

3000Vac 

500Vdc 

Factory Test 

5s 

2000Vac 

2000Vac 

500Vdc 

Field Test 

2s 

2000Vac 

2000Vac 

500Vdc 

Cut-off current setting  >20mA 

>20mA 

>1mA 

 

Summary of Contents for HSEUREG07201.015

Page 1: ...IN Rail Specification Voltage programming from 0V Multi interface 0 10V 0 20mA Sense Shutdown remote ON OFF N 1 parallel operation Natural convection Precise dynamic response on load change Designed for long life under full stress Strong input filters High reliability shock vibration proof Over Voltage and continuous short circuit protection EMI EMS EN61000 6 2 3 EN55032 class B EN61010 1 EN61010 ...

Page 2: ...atural convection The 1kW models use a forced air cooling system with a fan In selecting the fan as with all our power supplies in our opinion we use with the German manufacturer EBM Papst the highest quality and most reliable devices in the world market Design Conception The HSEUREG power supply series realizes high programmable power in a space saving housing Latest generation electrical devices...

Page 3: ...n protective electrical separation 60Vdc Analogue Interface see table protective electrical separation 60Vdc working impedance 500Ω Accuracy 1 5 Interface Latency Interface 15ms including signal latency for 0 Umax programming Start up Delay Typ 250ms Softstart Typ 100ms Start up from Shutdown Typ 250ms Response Load Change 1ms 10 100 100 10 Base Load None Efficiency 230Vac 90 typical Short Circuit...

Page 4: ...unctional interface 500 Ω working resistance with voltage programming 2 Ureg Input 3 Sense Input Sense Control none Compensation max 2V per load line 4 Sense Input 5 Remote Input External Shutdown Remote ON OFF Open Collector or Switch Voltage drop 1V with typical 2 3mA 6 Remote Input Programming Interface Ureg The standard programming of the HSEUREG Series is an analogue interface The output volt...

Page 5: ...o allow proper operation Remote Sensing Schematics Although the HSEUREG sense block is simpler it applies to the shown schematics Please note that the HSEUREG has no AUX connection feature and that the sense block has only connections We recommend twisted sense lines Local Sensing Remote Sensing Compensation of Load Line Drop Voltage Sense battery charger operation mode Remote Sensing as a battery...

Page 6: ... sections of all power supplies to the busbar or to the star point are identical Allow proper connection for low contact resistance If you want to use the sensing function connect it also to the star point or busbar To avoid measurement errors select the line length from the neutral point or from the busbar to the load as short as possible and use the maximum possible conductor cross section The H...

Page 7: ...rein a failure or malfunction could result in injury or death Mechanics ST HD Baseplate Cooling Temperature Management The temperature management of the HSEUREG series provides a direct dissipation of the main energy losses The internal coolers of the output diodes and the power FETs connect to the back plate cooler It is possible to dissipate about 40 50 of the energy losses out of a system while...

Page 8: ...a free air space of 50mm top bottom and 10mm sidewalls is required and for active devices 15mm space from the sidewalls One can use the DIN Rail installation equipped standard with our patented 35mm DIN Rail bracket according to EN60715 It is easy to mount dismount while snaping it onto the 35mm DIN Rail no tools necessary It is not allowed to install the HSEUREG in other mounting direction then b...

Page 9: ... accordance with EN 60999 a x b ø 5 4 x 5 1mm 5 3mm 2 8 x 2 4mm 2 5mm Pitch P 10 16mm 5 08mm Wire Stripping Length fine wired Nominal Cross Section Wire End Ferrule Stripping Length Wire End Ferrule Stripping Length 0 25mm H0 25 5 5mm H0 25 10 HBL 8mm 0 5mm H0 5 6 6mm H0 5 12 OR 8mm 1 0mm H1 0 6 6mm H1 0 12 GE 8mm 2 5mm H2 5 12 12mm H2 5 19D BL 14mm 4 0mm H4 0 12 12mm H4 0 20 GDR 14mm 6 0mm H6 0 2...

Page 10: ...bolts or operation outside the specified herein specification or in an unsuitable environment has the immediate loss of warranty to follow We disclaim any responsibility for any resulting damage to persons or things 4 Note The device must not be operated without an upstream circuit breaker CB We recommend the use of C Type 16A for 230Vac or 25A for 115Vac It is prohibited to use the unit without P...

Reviews: