2 For your safety
NOTE: Only qualified Schildknecht AG personnel may intervene in the hardware
and software.
A
WARNING!
High electrical voltages!
Death or serious injury due to electric shock. Due to a defect of the power supply
unit, voltages higher than 120 V DC or 50 V AC may be applied to touchable
parts.
→ Only use a power supply that allows max. 60 V DC or 25 V AC in the event of
a fault. It must conform to SELV or PELV.
→ The power supply must be SELV and LPS compliant according to UL/IEC
60950-1 or ES1 and PS2 compliant according to UL/IEC 62368-1.
Protective measures of the operator of the machine
• Observe the instructions in this manual.
• Observe the test specifications in the operating instructions of all
connected components.
Electromagnetic radiation
Keep a minimum distance of 20 cm from the
antennas while operating the equipment.
2.2 Intended use
The DATAEAGLE transmits data in industrial applications. It is designed
according to EN 60529 for protection class IP20 (Compact) or IP65 (X-treme)
and can be used in control cabinets up to protection class IP67.
The DATAEAGLE may only be used for the cases provided for in the operating
instructions and manual and only in conjunction with the third-party devices
and components recommended or approved by Schildknecht AG.
Correct and safe operation of the product requires proper transport, storage,
assembly and installation, as well as careful operation.
Intended use also includes EMC-compliant electrical installation. The module
is intended for use in an industrial environment. Radio interference may occur
when used in residential areas.
• When using the module in residential and mixed areas, observe the
applicable standards.
Manual
DATAEAGLE 6000 Series - Wireless CAN
9
Summary of Contents for DATAEAGLE 6000 Series
Page 2: ...Manual DATAEAGLE 6000 Series Wireless CAN 2...
Page 61: ......