9
ENGLISHENGLISH
Installation, use and maintenance instruction manual
▪
Ed. 07/2018 Rev. 00
TECHNICAL DATA SHEET: FC1337
Dimensions
Width
340 mm
Depth
530 mm
Height
48 mm (hob area)
105 mm (valves area)
Weight
3.8 kg
Hob Unit
(straight valves with
bypass Ø 0.36 mm)
Nominal values:
1 x AUXILIARY burner (AUX)
Pn 1.00 kW – injector ø 0.50 mm – consumption 72.50 g/h
1 x SEMIRAPID burner (SR):
Pn 1.75 kW – injector ø 0.65 mm – consumption 127.0 g/h
Device Class
(EN 30-1-1 4.3)
CLASS 3 – Recessed hob unit
Device Category
(EN 30-1-1 5.1.1.2)
CATEGORY I
Admitted Gases
family
(EN 437)
(EN 30-1-1 4.2.2.4)
GAS OF THE THIRD FAMILY
▪
I3 B/P
▪
I3+
Gas Supply
CATEGORY I3 B/P
▪
Butane (G30) 30 mbar
▪
Propane (G31) 30 mbar
CATEGORY I3+
▪
Butane (G30) 28-30 mbar
▪
Propane (G31) 37 mbar
Electric Connection
(only for “E” version with
electronic lighting)
ELECTRIC CONNECTION IN EXTRA-LOW VOLTAGE - 12V / DC
Lighting
▪
S (MANUAL) – using external igniter
▪
E (ELECTRONIC) - 12 V/DC GENERATOR - SPARK - 10Kv @ 30 pF
▪
P (PIEZOELECTRIC) – Mechanically/manually operated piezoelectric igniter inserted
in hob unit
Gas Connection
Galvanised steel train: Ø 8 mm - 1 mm thick
smooth end piece (30 mm) suitable for press fitting connecting with rigid / flexible hose
Gas Capillaries
Copper capillary pipes: Ø 4 mm – 0.5 mm thick
Materials
▪
Stainless steel AISI 304
▪
Glass
▪
Chromium-plated iron
▪
Zama
▪
Brass
▪
Copper
▪
Galvanised steel
▪
Aluminium alloy
▪
Enamelled steel
▪
Epdm
Declaration of
Conformity
(GAR 2016/426/EC)
▪
no asbestos
▪
suitable materials according to chapters 2 and 3 (Annex I)
▪
there are no welds with melting point lower than 450°C
▪
flammable materials were not used
▪
the materials are suitable according to the requirements of chapter 3.7
Summary of Contents for FC Series