8
INSTALLATION
– MAINTENANCE – ADJUSTMENTS
The information and operations illustrated in this section are dedicated exclusively to fitters.
The installation and all adjustments, transformations and maintenance operations shown in this section must be carried
out exclusively by qualified personnel, in observance of local legislation
(Law no. 46/90 and DPR 447)
.
If in doubt, contact Technical Assistance.
Incorrect installation or adjustment may cause damages to people, animals or things. The manufacturer declines all
responsibility for installation or adjustment which do not comply with the instructions given in this section.
Installation must conform to
UNI 7131
(the latest revision).
Inserting and fastening the appliance
Remove the appliance from the packaging, ensuring that it is complete and undamaged. If in doubt, do not proceed and contact
the dealer of Technical Assistance immediately.
Remove the protective plastic.
The material of items adjacent to the appliance (furniture( must resist temperature surges of at least 65 K (90°C with a room
temperature of 25 °C).
Also observe the critical distances from the adjacent walls/furniture.
Critical distances (X and Y) are the same for all models. See figure 3 below.
N.B.: In figure 3, the side of the furniture is shown to the left of the appliance. If you wish to install it on the right, observe the same
critical distances indicated in the table (Y).
Make sure that the distance between the pan stand of the appliance and any furniture of hoods above the appliance is at least 650
mm.
Any lateral work surfaces within critical distance Y must remain below the height of the appliance surface.
Figure 3
The appliance must be fastened to the unit using the screws supplied with it.
Fasten the appliance through the appropriate holes using the screws supplied;
The appliance is now fastened to the unit. For any maintenance operations requiring the dismantling of the appliance from the unit,
simply loosen the 4 screws.
Gas connection
Before connecting the gas supply, make sure that the local distribution conditions (type and pressure of gas) and the adjustment of
the appliance are compatible. The appliance adjustment conditions are indicated on the data plate on the underside.
The appliance input consists of a gas ramp with the end facing sideways, to simplify installation.
The end is cylindrical,
8 mm diameter
, unthreaded, for at least 30 mm. Where permitted by the installation standards in force,
connection to the gas main may take place using a flexi-pipe with a gas-proof press fitting (complete with ogive).
In the specific case of built-in installation, UNI 7131 forbids direct connection of the appliance to the gas bottle by flexi-pipe. It is
therefore necessary to connect the appliance to a fixed system (UNI 7129), which will be connected to the gas bottle and the
appliance by flexi-pipes (UNI 7140) with a rubber insert support and relative clamps (UNI 7141). The flexi-pipe must have a
maximum length of 1.5 m, without intermediate joints, and must not run through two different rooms.
The connections must not
Model
W (mm)
D (mm)
X (mm)
Y (mm)
PC1320
290
250
55
100
PC1321
320
300
55
100
PC1322
350
340
55
100
PC1323
450
340
55
100
Summary of Contents for PC Series
Page 1: ...MANUAL INSTRUCCTION PC series FC series FN series PVseries...
Page 45: ...45...
Page 46: ...46...