3. BILGE PUMP AND WATER DRAINAGE
A -
Automatic of 1,100 gallons/hr or 4,158 liters/hr
B -
Heavy storms could easily flood the cockpit
C -
Cracks in the hull will permit water infiltration into bottom
DECK
BOW
3/4 “ HOSE
A
C
B
STERN
KEEL
DIAGRAM OF BLIGE PUMP AND DRAINAGE SYSTEM
CARE AND MAINTENANCE OF BLIGE PUMP
•
Occasionally check your pump to be certain debris is not jamming
the impeller and/or float within the housing. Use the test knob by
rotating in a clockwise direction. Careful attention will guarantee
outstanding pump performance.
•
To clean the water chamber, remove pump housing from the mount-
ing base by pressing in tabs on sides. Lift the pump housing away.
•
To clean the impeller, remove the impeller guard screw and lift the
impeller guard.
•
Remove all debris that has accumulated in pump chamber and
around the impeller. Ensure that all debris is removed from strainer
slots around the pump base.
•
Inspect the impeller to ensure that it is firmly attached to shaft and
is not cracked or broken.
•
Replace impeller guard, screw, and pump housing on base.
•
Be certain that all tabs are fully engaged.
•
Periodically check the electrical connections to ensure they are
water-resistant and mounted high and dry.
•
Do not use household cleaners on the pump because many of them
may damage the pump materials.
REMOVE (1) SCREW
IMPELLER GUARD
DEPRESS (2) TABS
p.8