Use two insertion profiles running parallel to the long
side frame.
Use two insertion profiles running perpendicularly to
the long side frame.
Maximum Load:
Uplift load 2000 Pa
≤
Downforce load 2000 Pa
≤
Maximum Load:
Uplift load 2400 Pa
≤
Downforce load 4000 Pa
≤
CS3k-p, CS3k-MS, CS6k-p, CS6k-M, CS6k-MS, CS6v-p, CS6v-M and CS6v-MS
Use two insertion profiles running perpendicularly
to the long side frame. An additional support
bar should be placed below the module. Use two
clamps on the support bar.
Maximum Load:
Uplift load 2400 Pa
≤
Downforce load 5400 Pa
≤
Use two insertion profiles running parallel to the long
side frame.
Maximum Load:
Uplift load 2400 Pa
≤
Downforce load 2400 Pa
≤
Use two insertion profiles running perpendicularly to
the long side frame.
Maximum Load:
Uplift load 2400 Pa
≤
Downforce load 4000 Pa
≤
CS6A-p, CS6A-M, CS6vL-MS and CS6A-MS